Operating Instructions Safety System MGB-L..B-PNA-... (PROFINET)

15

Important!

The following applies to systems with guard locking: The system enters into a
latching fault when the escape release is actuated. See System status table on
page 31, status Signal sequence erroneous (DIA1 flashes 7 times).
The system might not enter into a latching fault if the escape release is actuated

very slowly.

Preparation of the escape release

1

Fit door handle

2

Insert actuation axis. The locking ring A must be in contact with

the escape release B

3

Tighten setscrew to 2 Nm

4

Fit protective sleeve

Figure 8: Preparing escape release

1

3

2

4

A

B

58

,5

4

D

4

(10)

55

,5

250

182

D + 13,5

3,5

D + 3

Example with mounting plates:

Actuation axis

Protective sleeve

Mounting

plates

(+ 4 mm per plate)

(+ 4 mm per plate)