Enerpac SafeLink User Manual
Page 2
Table 1 - General Specifi cations
IP Rating
Meets IEC IP67 Standards. Dust tight, immersion up to one meter.
SEND UNIT
INPUT CAPABILITIES:
SLS-1 & SLS-2: Monitors
two inputs and contains
a communications check
channel (For use only
with receive unit Model
SLR-1).
SLS-3: Monitors three
inputs (For use only
with receive unit Model
SLR-2).
Radio Frequency
2.4 GHz, Global Standard
Transmit Power
21 dBm conducted
Input Power for Receive Unit (SLR-1, SLR-2)
+ 10 VDC to + 30 VDC Supplied by machine control.
Battery for Send Unit (SLS-1, SLS-2, SLS-3)
3.6 Volt Lithium Battery, Size D (Xeno XL-205F or equivalent).
Outputs
+ 24 VDC, NMOS Sinking
FCC Rating
FCC part 15, Subpart C, 15.247
Receive Unit Communication Protocols
(SLR-1, SLR-2)
Modbus RTU RS485. Modbus TCP/IP or Ethernet IP when
system is equipped with SLEB-1 Ethernet Bridge.
Receive Unit Outputs (SLR-1, SLR-2)
24 VDC, Maximum of 6 per unit, NPN Sinking
2
4.0 MOUNTING DIMENSIONS
Figure 1, Mounting Dimensions
D2
D4
D1
D5
D6
D8
(4X)
D3
D2
D4
D1
D5
D8
D6
(4X)
D3
SLS-1 Send Unit
SLS-2, SLS-3 Send Unit
D2
D1
D4
D5
D7
D6
(4X)
D3
SLR-1, SLR-2 Receive Unit
D2
D1
D5
D4
D7
D6
(4X)
D3
SLEM-1 Expansion Module
D1
D2
D4
D5
D7
D6
(4X)
D3
SLEB-1 Ethernet Bridge
Note: Antenna not shown.
Note: Antenna not shown.
Dimensions
Item
inch
mm
D1
3.18
80,8
D2
2.56
65,0
D3
Ш 0.22
Ш 5,5
D4
2.56
65,0
D5
3.16
80,1
D6
2.23
56,6
D7
4.20
106,7
D8
3.67
93,2
3.0 SPECIFICATIONS