11.0 MAINTENANCE
Follow these instructions to perform basic maintenance tasks.
11.1 Replacing The Main Body Gasket
Check the main body
gasket every time the
device is opened.
Replace the gasket
when it is damaged,
discolored, or showing
signs of wear.
The gasket must be:
• Fully seated within its
channel along the full
length of the perimeter,
and. . .
• Positioned straight
within the channel with
no twisting, stress, or
stretching.
11.2 Replacing The Rotary Dial Cover
Check the o-ring on the rotary switch access cover whenever the
access cover is removed. Replace the o-ring when it is damaged,
discolored, or showing signs of wear.
The o-ring should be:
• Seated fi rmly against the
threads without stretching
to fi t or without bulging
loosely, and. . .
• Pushed against the
fl anged cover.
When removing or closing
the rotary switch access
cover, manually twist the
cover into position.
Do not allow cross-
threading between the
cover and the device’s
face.
Once the cover is in place and manually tightened, use a small
screwdriver (no longer than 5 inches [127 mm] total length) as a
lever to apply enough torque to bring the rotary switch access
cover even with the cover surface.
11.3 Battery Replacement
To replace the lithium “D” cell battery in the SLS-1, SLS-2 or
SLS-3 send unit, follow these steps:
1. Remove the four screws mounting the device face plate to
the housing and remove the face plate.
2. Remove the discharged battery and replace with a new
battery. Use only a 3.6V lithium battery from Xeno, model
number XL-205F.
3. Verify the battery’s positive and negative terminals align to
the positive and negative terminals of the battery holder
mounted within the case. The negative end is toward the
spring. Caution: There is a risk of explosion if the battery is
replaced incorrectly.
4. After replacing the battery, allow up to 60 seconds for the
device to power up.
Figure 28, Battery
(SLS-1, SLS-2 and SLS-3 Only)
When removing the battery, press the battery towards the
negative terminal to compress the spring. Pry up on the battery’s
positive end to remove from the battery holder. Properly dispose
of your used battery according to local regulations by taking it to
a hazardous waste collection site, an e-waste disposal center, or
other facility qualifi ed to accept lithium batteries.
WARNING: As with all batteries, these is a fi re,
explosion, and severe burn hazard risk. Do not burn or
expose the battery to high temperatures. Do not
recharge, crush, disassemble, or expose the contents to water.
12.0 PRODUCT WARRANTY
SafeLink products are warranted by Enerpac to be free from
defects in material and workmanship for 2 years following the
date of shipment. Enerpac will repair or replace, free of charge,
any SafeLink product which, at the time it is returned to the
factory, is found to have been defective during the warranty
period. This warranty does not cover damage or liability for
misuse, abuse, or the improper application or installation of the
SafeLink product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF
ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED
(INCLUDING, WITHOUT LIMITATION, ANY WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE), AND WHETHER ARISING UNDER COURSE OF
PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the
discretion of Enerpac, replacement. IN NO EVENT SHALL
ENERPAC BE LIABLE TO BUYER OR ANY OTHER PERSON
OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES,
LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL
OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT
DEFECT OR FROM THE USE OR INABILITY TO USE THE
PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY,
STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR
OTHERWISE.
Enerpac reserves the right to change, modify or improve the
design of the product without assuming any obligations or
liabilities relating to any product previously manufactured by
Enerpac.
Figure 26, Main Body Gasket
Figure 27, Rotary Switch Cover