beautypg.com

Troubleshooting: error messages and alarm, Table 5. error messages and next steps – Despatch RFD Series User Manual

Page 39

background image

RFD

Oven Series Owner’s Manual

T

ROUBLESHOOTING

Version 1

39

Copyright © 2012 by Despatch Industries.

All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.

Conditions

Actions

2. Check motor for proper operation and direction of rotation.

B. Cold by door

1. See A-1.
2. Check door seals.
3. Open optional supply louvers close to door.

C. Positive pressure

in chamber

4. Close fresh air damper.
5. Open exhaust damper.
6. Refer to Damper Control Section 3.2 for more information.

D. Negative pressure

in chamber

1. Close exhaust damper.
2. Open fresh air damper.
3. Open optional supply louvers slightly.

7.3. Troubleshooting: Error Messages and Alarm

Table 5 lists the more common error messages, the possible problems and remedies.

Table 5. Error Messages and Next Steps.

Alarm Status

Possible Problem

Next Step

HI LIMIT LED ON

Problem with thermocouple

High Limit setpoint has been
exceeded.

Once the problem has corrected,
press RESET.

DEV HOLD LED flashing

Oven temperature has not
entered (or dropped out of) the
Auto Hold band and the soak
timer has stopped

Program a slower ramp rate or if oven
is not heating check heater circuit.

Top PV displays OPEN

Control thermocouple is
disconnected or broken

Repair or replace the thermocouple.

HLPV displays OPEN

High Limit thermocouple is
disconnected or broken

Repair or replace the thermocouple.