6.2. Maintenance Schedule

Preventive

Maintenance

(Refer to Section)

Daily

Weekly

Monthly

Every
Three

Months

Every

Six

Months

Annually

As

Needed

General

Avoid placing load
too close to supply
duct (5.1)

X

Visually inspect for
dirt, debris and free
movement of parts
and controls.

X

Clean as needed

X

Inspect door seals
for proper seating,
damage and/or
tears

X

Inspect door
operation. Doors
should open and
close securely,
without jerking or
slamming.

X

Check optional
Disconnect Switch
(2.5.1)

X

Time to temperature:
record heating times
for similar loads. If
heating times are
slowing, it could
indicate a need for
maintenance.

X

Ventilation

Check fresh air
damper (3.2)

X

Check fan vibration:
supply and exhaust
(6.3)

X

Inspect optional
louvers (3.3)

X

Check fan rotation
(5.3.1)

X

Electrical

Test airflow switch
(6.5)

X