Tear down procedures – Condux Deluxe Blower User Manual
Page 34

34
!wARNING: Air Block Assembly contains compressed air when blower
is operated. Opening Air Block while under pressure may cause serious
personal injury. Ensure blower is depressurized before removing Air
Block cover.
7. Remove
Cable Grip from receiving end of Conduit.
8. If electronics stop blower before
Cable Carrier exits, restart blower, making sure
speed is within minimum and maximum allowance. Also see Troubleshooting
Guide.
Tear Down Procedures
!wARNING: Air Block Assembly contains compressed air when blower is
operated. Opening Air Block while under pressure may cause serious personal
injury. Ensure blower is depressurized before removing Air Block cover.
A. REmOVE POwER FROm uNIT.
1. Turn off compressed air by closing the
Air Control Valve at the blower
(Figure 71). Shut off air at the compressor and decompress air hose.
Depressurize the air block by turning the air control valve to the 9 o’clock
position (Figure 72). Remove air hose when system is relieved of pressure.
2. Raise
Tractor Drive Cover with turn crank (Figure 73).
3. Turn off
hydraulic Power Supply and disconnect hydraulic hoses (Figure 74).
Keep all connections free of dirt and particles. Use hose end caps (supplied).
4. Disconnect electronic cords.
!wARNING: Escaping fluids under pressure can penetrate the skin and
cause serious personal injury. Release pressure before disconnecting
hoses.
12.
Figure 71. Turn Off Air at the
Air Block
Figure 72. Decompress Air Block