beautypg.com

Tear down procedures – Condux CableGlider FO Cable Puller User Manual

Page 16

background image

16

Tear Down Procedures

A. REmOvE HYDRAULIC POwER SUPPLY

1. Stop the puller by releasing the foot pedal to its neutral position.

2. Shut off the hydraulic power supply.

3. Push the foot pedal down and lift up at least 3 times to relieve the hydraulic system’s back pressure.

!wARNINg: Escaping fluids under pressure can penetrate the skin and cause

serious personal injury. Release pressure before disconnecting hoses.

4. Disconnect all hydraulic supply hoses. Cap all hose ends and connectors to guard against contamination.

b. DISCONNECT ELECTRONICS

!DANGER: The electronic control box is an electrical device. Electric shock hazards

exist that could result in severe personal injury or death. Follow all electrical safety

precautions in this manual.

1. Turn off the electronic control box.

2. Disconnect the power cord between the electronic control box and the 12 Volt DC power supply.

3. Unplug the sensing cord from the puller and the control cord from the foot control valve assembly.

C. REmOvE CAPSTAN FROm PULLER

1. Push inward on the capstan and rotate it counterclockwise (figure 19).

2. Align the capstan’s slots with the shaft’s pins and pull off.

10.

Figure 19. Capstan Disassembly