4 • COATS Heavy Duty Tire Changer

Electrical Installation

The H.I.T. 6000 requires 220 volt, 3 phase or optional

single phase power source. CAUTION: Only a licensed

electrician should install power source and hook up the

H.I.T. 6000.

Important: Installation of this unit in an area where

gasoline, gasoline fumes, or other flammable vapors are

present requires a motor/switch riser kit (PN 7120433)

to meet national electrical codes; including paragraphs

500-4, 501 (1-8), 511 (1-5), PP 70-377.

Disconnect power source and check with volt-ohm

meter to assure power is off before connecting wires

of machine.

CAUTION

Motor rotation must be clockwise looking
at top of motor. If counterclockwise, reverse
any two of the power wires.

Principal Operating Parts

Air Installation

A quick coupler is provided for disconnecting the air

supply during maintenance procedures. The male fitting

is on the inset hose. The female is in the parts bag for

installation on the owner’s air supply hose.

For lubrication of internal air system, a lubricator

should be installed in the air supply line.

General

The H.I.T. 6000 does not require bolting to the floor.

However, if desired, the two holes located at the

back of the machine, used for mounting on the pallet,

should be used. DO NOT BOLT AT THE FRONT OF THE

MACHINE.