beautypg.com

CHAMPION CG Manual User Manual

Page 21

background image

13

Problem

Cause(s)

Solution(s)

Troubleshooting





Flowing water supply line pres-
sure measured at the glass-
washer exceeds 95 psi [655
kPa].

Defective solenoid valve(s).

Defective AUTO-FILL switch.






Rinse water pressure too high




Chemical container(s) are
empty.


Chemical supply line(s) are
clogged.




Chemical supply and/or pump
tube(s) are broken.

No power to chemical dispens-

ing pump(s).



Dispensing pump is defective.



Chemical pumps out of
adjustment

Water flows into glasswasher

when ON/OFF switch is in
the OFF position.

Chemical(s) are not flowing into
the glasswasher.

Reduce flowing water pressure

measured at the glasswasher
below 95 psi [655 kPa].

Authorized service agent may

rebuild or replace the solenoid
valve(s).

Incoming water pressure must be

5 PSI/35 kPa on pressure gauge

located on right-side of glasswasher
lower compartment

Refill the container(s).


Remove the supply line(s) from the

chemical containers and flush with

warm water.

Replace supply line(s) and/or pump
tube(s).

Authorized service agent must inspect

and repair

Chemical supplier must adjust
chemical pumps.

Authorized service agent may replace

chemical dispensing pump.

Service agent replace the switch.