7

Operation

MIX

Plug machine power cord into a

208-230VAC/60/1,15 A

wall recep-

tacle. Turn main power and water

service ON.

Remove lower wash tank scrap screen.

Make sure a glass

is against the conveyor

stop switch, Push the rocker

switch UP to the ON

position until the wash

tank is full of water.

Then, push and hold each

chemical Prime button

until chemical supply

tubes are full.

The incoming cold water

supply temperature must

be a minimum temper-

ature of 75°F/24°C.

Adjust the temperature of

the incoming cold water temperature

by opening or closing the mixing valve

located between the hot water and the

cold water solenoid valves.

Check the cold water temperature

gauge and the cold water pressure

gauge as you adjust the mixing valve.

The minimum temperature should be

75°F/24°C. The pressure gauge should

read a flowing pressure

of 4-6 psi/24-36 kPa.

Check the wash tank

temperature gauge

for 140°F/60°C-

160°F/71°C.

Place glassware on

the conveyor.

The conveyor

stops automatically

when when

the clean glassware

operates the conveyor

stop switch.

Install the drain/

overflow tube into

the drain located

at the front of the

wash tank bottom.

Re-install the

scrap screen

removed

in Step 2.

Pull the chemical

pick-up tubes out

of the machine

Colored labels I.D. each tube

Place tube into its supply container.

On

Off

Flush

MIX

Pressure

Temperature

Wash Tank Heat

Prime

Prime

Prime

Label

Quick Operation Guide

The glass washing machine is designed

to automatically wash a wide variety of glassware.
The glass washer consists of a wash section and

rinse section. Glasses rotate on a conveyor

through each section. A wash tank in the lower

compartment holds heated wash water. The water

level in the wash tank is maintained by a float and

cam-operated switch. The wash tank water

temperature is controlled by a heater and a

thermostat. The rinse water is supplied from

the cold water supply. Chemicals are auto-

matically dispensed by built-in chemical pumps

1

2

3

4

6

5

7

8

7

4

6

7

8

1

2

3

5

Red

Label

Detergent

Sanitizer

White

Blue

Label

Rinse-aid

Det.

Sani

R/A