Installation

Priming the Chemical Injectors and Approximate Chemical Settings

Each chemical injector can be adjusted using its prime button and concentration adjusting screw.
These controls are located on the right side of the control box located in the lower compartment of the
glasswasher. The white injector rotors are visible through the control box window.

ALL OF THE CHEMICAL SETTINGS BELOW ARE APPROXIMATIONS.

CONSULT A QUALIFIED CHEMICAL REPRESENTATIVE TRAINED IN THE USE OF THE TEST

EQUIPMENT REQUIRED FOR TAKING SAMPLES AND PERFORMING ADJUSTMENTS.

1.

Priming the Pumps:

Make sure the proper chemical pick-up tube is in its supply container, then

push and hold the prime button until the detergent, sanitizer and rinse-aid feed tubes are full of

chemical.

2.

Approximate Chemical Settings:

The approximate chemical volume dispensed by the chemical injector rotors can be

determined by counting the number of revolutions of the injector rotor.

Detergent - 1 revolution in 1-second of the detergent pump rotor ~ 0.35% concentration.

Sanitizer - 1 revolution in 5-seconds ~ 12.5 ppm of Iodophor or 50 ppm of chlorine.

Rinse-aid - 1 revolution in 8-seconds ~ the median volume recommended.

Turn the Injector Concentration screws clockwise to increase or counter-clockwise

to decrease the volume of dispensed chemical.

3.

The detergent chemical setting must be performed when the hot-water fill solenoid valve is open.

The hot-water valve is open when the power switch is in the ON position during initial fill and when

the detergent tank float assembly calls for hot water

The sanitizer and the rinse-aid setting can be performed whenever the cold-water fill solenoid valve

is open. The cold-water fill valve is open whenever the glasswasher power switch is ON and

the conveyor is turning. A separate rinse-aid is not needed when Iodophor is used as a sanitizer.

Turn the Injector Concentration Screw fully counter-clockwise until the rinse-aid injector rotor stops

turning.

+

-

Push to prime

Turn CW to increase(+)

CCW to decrease (-)

DET

SAN

R/A

Chemical Injector Prime and Concentration Controls

Detergent

Sanitizer

Rinse-aid

Rotor