Clamp application – BAND-IT S100 Classic Air Tool User Manual
Page 10
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
P: 1-800-525-0758
F: 1-800-624-3925
Document # P09287 rev. L
© Copyright
BAND-IT-IDEX, Inc. 2006
All rights reserved
www.BAND-IT-IDEX.com
Page 10 of 18
S10099
Classic Air Tool
VALVE
STEP 1
TURN PRESSURE INDICATOR KNOB UNTIL
INDICATOR COINCIDES WITH THE
PRESSURE REQUIRED FOR THAT
PARTICULAR BAND WIDTH AND MATERIAL
TYPE. SEE PAGE 6 OR RIGHT SIDE OF
TOOL CYLINDER FOR RECOMMENDED
PRESSURE
SETTINGS.
STEP 2
INSERT CLAMP TAIL INTO NOSE OF
TOOL WITH BUCKLE UP. PUSH VALVE
HANDLE TO PULL-UP POSITION AS
SHOWN. (SHOULD TOOL FAIL TO
OPERATE, PUSH ON SHUT-OFF VALVE.)
STEP 3
WHEN SHUT-OFF VALVE TRIPS,
RETURN VALVE HANDLE TO NEUTRAL
POSITION (HALF WAY BETWEEN PULL-
UP AND RETURN POSITIONS).
STEP 4
WHEN PRESSURE BLEEDS TO HOLDING
PRESSURE AS INDICATED ON PRESSURE
GAUGE, ROLL BUCKLE UNDER SHEAR HOOK
AND PULL CUT OFF HANDLE.
STEP 5
PULL VALVE HANDLE TO RETURN
POSITION TO EJECT TAIL.
NOTE:
WHEN APPLYING OVERSIZED CLAMPS,
LIFT UP RAIL COVER, BACK OUT SOCKET
HEAD CAP SCREW LOCATED ON TOP OF
PISTON ROD HEAD TO CLEAR BAND PATH
INSIDE PISTON ROD HEAD FOR MORE
THAN ONE GRIP PER CLAMP.
RETURN SCREW BACK TO ITS ORIGINAL
POSITION WHEN MULTIPLE GRIPS ARE
NO LONGER REQUIRED. THREADED END
OF SET SCREW INSIDE PISTON ROD
HEAD IS USED TO EJECT CLAMP TAIL
SCRAP OUT OF FRONT OF JUNIOR HEAD.
SEE PAGE 6 FOR IMPORTANT ADVICE
AND WARNINGS.
Clamp
Application