beautypg.com

Available software, Power supply – 2N PRI Gateways - User Manual User Manual

Page 8

background image

6


1.1.3. Front side division for gateways with VoIP interface

The subrack width is divided into an 8HP-wide mains panel and 19 4HP-wide modules in

the following sequence (from right to left):

Board Type

Size

StarGate

BlueStar

BlueTower

VoIP

board

12HP

YES YES NO

CPU board

4HP

YES

YES

YES

AUX board

4HP

YES

YES

YES

PRI board

4HP

NO***

NO***

YES

GSM board

4HP

Up to 16x

Up to 8x

Up to 4x

3G card (one channel)

4HP

Up to 16x

Up to 8x**

Up to 4x**

3G card (two channels)**

4HP

Up to 16x

Up to 8x

Up to 2x

Thin VoIP card

4HP

YES

YES

YES

Internal antenna splitter BlueStar

32HP

NO

YES

NO

Internal antenna splitter BlueTower

8HP

NO

NO

YES*

1.2. Available Software

PRIGW program

- tool to configure and control of the gateway

Accounter tools

- tools for automatic download and handling with CDR information

1.3. Power Supply

1.3.1. Description

The system uses an industrial mains supply unit with primary (input) voltage of 100-

240VAC 50/60Hz and secondary (output) voltage of 5V/30A or 5V/4A with natural cooling and
an auxiliary external ventilator , which is switched on automatically whenever the power supply
temperature exceeds 70°C. The supply is designed with a 30% reserve even under the
maximum load.

Type of power supply

Active cooler

StarGate

BlueStar

BlueTower

Internal 90-260V/50-60Hz = 5V/30A

YES

YES

YES

NO

Internal 48DC

YES

YES

YES

NO

Internal 90-260V/50-60Hz = 5V/10A

NO

NO

NO

YES

*type of power supply depends on order number