6.9 MACHINE PERSONALITY SETTINGS
NOTE: Personality settings can be adjusted within the
adjustment range in order to achieve optimum
machine performance.
Table 6-6. Personality Ranges/Defaults
FUNCTION
PERSONALITY
RANGE
DEFAULTS
DRIVE
ACCELeration
0.1 to 5.0s
2.0
DECELeration
0.1 to 3.0s
2.0
FORward MINimum speed
0 to 25%
4
FORward MAXimum speed
0 to 100%
30
REVerse MINimum speed
0 to 35%
4
REVerse MAXimum speed
0 to 100%
30
ELEVATED MAXimum speed
0 to 50%
15
CREEP MAXimum speed
0 to 45%
20
Engine RPM
800 to 2900
1800
TOWER LIFT
ACCELeration
0.1 to 5.0s
1.5
DECELeration
0.1 to 3.0
0.5
MlNimum UP speed
0 to 60%
39
MAXimum UP speed
0 to 100
100
MINimum DOWN speed
0 to 60
38
MAXimum DOWN speed
0 to 100
100
Engine RPM
800 to 2900
1800
UPPER LIFT
ACCELeration
0.1 to 5.0
2.5
DECELeration
0.1 to 3.0
0.7
MlNimum UP speed
0 to 60%
30
MAXimum UP speed
0 to 100
67
CREEP Maximum UP speed
0 to 65
55
MINimum DOWN speed
0 to 60
45
MAXimum DOWN speed
0 to 100
76
CREEP maximum DOWN speed
0 to 75
55
Engine RPM
800 to 2900
1800