SECTION 4 - BOOM & PLATFORM
4-64
– JLG Lift –
3120740
Turntable Sensor Faulted
8/1 TURNTABLE FAULTED
If the system detects that the Chassis tilt sensor frequency
outside the 100Hz +/- 5Hz range or the duty cycle is out-
side 50% +/- 21% range the control system shall report a
fault
Solution:
• Inspect wire harness going to the sensor and UMS
module.
• Inspect sensor mounting.
• Replace sensor.
EEPROM checksums failure
9/9 EEPROM FAILURE – CHECK ALL SETTINGS
A critical failure occurred with the EEPROM. Personalities,
machine configuration digits, etc. may be reset to default
values and should be checked.
Solution:
• Contact JLG if message is reoccurring.
4.18 UMS TROUBLESHOOTING AND FAULT
MESSAGES - ADE MACHINES
Backward Stability Concern Message
2/5 UMS SENSOR BACKWARD LIMIT REACHED
When the upright angle relative to the turntable is higher
than +2.5° (away from the work platform), tower lift down
will be disallowed immediately. Tower Lift Down will be re-
allowed when the upright angle relative to the turntable is
less than 2.0. If Tower Lift Down is disabled for more than
1.5 seconds, the ground boom malfunction indicator
lamp, upright tilted lamp and platform alarm will light/
sound continually and a fault shall be raised. These condi-
tions will be latched along with Tower Lift Down until the
upright angle is less than 2.0 for 2 seconds and the
Tower Lift Down command is returned to neutral.
Solution:
• Inspect sensor mounting.
• Verify sensor calibration on level pad.
• Follow the corrective action listed on decal 1702265
located near the red knob of the machine.
• Inspect machine hydraulics. Refer to Holding Valve
Checks in Section 5 - Hydraulics.
Forward Stability Concern Message
2/5 UMS SENSOR FORWARD LIMIT REACHED
When the upright angle relative to the turntable is less
than –4.0° for longer than 1.5 seconds, the ground control
boom malfunction indicator lamp, the platform malfunc-
tion indicator lamp, and platform alarm will light/sound
continually and a fault will be raised. The light/alarm signal
will stop only when the upright angle reaches values
greater than –3.0° for 2 seconds.
Solution:
• Inspect sensor mounting.
• Verify sensor calibration on level pad.
• Tower lift down.
• Inspect machine hydraulics. Refer to Holding Valve
Checks in Section 5 - Hydraulics.
Auto Detection Input Low Message
2/5 AUTO DETECTION INPUT LOW
If the UMS detects a valid ground module software version
but digital input 2 is not tied high the UMS module shall
report a fault.
Solution:
• Inspect wire harness, there should be 12 volts going
into pin J1-5 (black connector) of UMS module.
UMS Sensor Communications lost
6/6 UMS SENSOR COMMUNICATIONS LOST
If the UMS detects a valid ground module software version
but digital input 2 is not tied high the UMS module shall
report a fault.
Solution:
• Inspect wire harness; CANbus communications are on
pins J2-9 & J2-10 (gray connector) of the UMS module.
• Using access level 1 of the UMS module, under “DIAG-
NOSTICS” CAN, RX/SEC and TX/SEC should be val-
ues greater than 0. Also “BUS OFF:” and “BUS ERR:”
should be 0 and “PASSIVE:” should be a low value.