Draining oil build up from the propane regulator – JLG 800A_AJ ANSI Service Manual User Manual
Page 34
SECTION 1 - SPECIFICATIONS
1-14
– JLG Lift –
3120740
19.Electronic Pressure Regulator (LP only)
Interval - 3 Months or 150 hours of operation
Comments - Drain oil build up. Refer to Draining
Oil Build Up From The Propane Regulator
20.Fuel Filter (Propane) - GM Engine
Interval - 3 Months or 150 hours of operation
Comments - Replace filter. Refer to Propane Fuel
Filter Replacement
Draining Oil Build Up From The Propane
Regulator
During the course of normal operation oils may build
inside the primary and secondary chambers of the pro-
pane pressure regulator. These oils may be a result of
poor fuel quality, contamination of the fuel supply
chain, or regional variation in the make up of the fuel. If
the build up of the oil is significant this can effect the
operation of the fuel control system. Refer to Section
1.9, Lubrication and Operator Maintenance for mainte-
nance intervals. More frequent draining may be
required if the fuel supply has been contaminated.
FOR BEST RESULTS WARM THE ENGINE TO OPERATING TEM-
PERATURE BEFORE DRAINING. THIS WILL ALLOW THE OILS TO
BE LIQUID AND FLOW FREELY FROM THE REGULATOR.
1. Move the equipment to a well ventilated area.
Ensure there are no external ignition sources.
2. Start the engine and bring to operating temperature.
3. With the engine running, close the manual tank
valve and run the engine out of fuel.
4. Push in the Emergency Switch once the engine
stops.
5. Disconnect the electrical connection to the LPG fuel
temperature sensor in the auxiliary fuel port of the
EPR.
6. Remove the retainer clip for the LPG fuel tempera-
ture sensor and remove the sensor from the regula-
tor body.
NOTE: Have a small container ready to collect oil that will
drain freely from the regulator at this point.
7. Once all of the oil has been drained, reinstall the
LPG fuel temperature sensor and reconnect the
electrical connector.
8. Open the fuel tank manual valve.
9. Start the engine and verify all connections are
secure.
10. Dispose of any drained oil in a safe and proper fash-
ion.