13 sauer piston pump s/n 0300121643 to present, Sauer piston pump s/n 0300121643 to present -42, Gauge port locations -42 – JLG 800A_AJ ANSI Service Manual User Manual
Page 322: Symbols used -42, Gauge and port information -42
SECTION 5 - HYDRAULICS
5-42
– JLG Lift –
3120740
5.13 SAUER PISTON PUMP S/N 0300121643
TO PRESENT
Table 5-3. Symbols Used
Symbol
Meaning
Symbol
Meaning
Non-reusable part, use a
new part
Inspect for wear or dam-
age
Option - either part may
exist
Note correct orientation
Internal hex head
Torque specification
O-ring boss port
Pull out with tool - press fit
Lubricate with hydraulic
fluid
Cover splines with instal-
lation sleeve
Apply grease /petroleum
jelly
Pressure measurement /
gauge location or specifi-
cation
The symbols above can be found in the pump illustrations. The legend
above is provided to define each symbol and explain its purpose.
Inlet port S
SAE J1926/1,
1.875-12
System gauge po
SAE J1926/1,
0.4375-20
Case drain po
rt L1
SAE J1926/1,
0.875-14
Outlet port B
SAE J1926/1,
1.3125-12
Case drain port L2
SAE J1926/1,
0.875-14
rt M2
Table 5-4. Gauge and Port Information
Port
Purpose
Range of Pump
Fitting
M2
System pressure
0-5000 psi [0-300 bar]
7/16 - 20 o-ring fitting
M4
Servo pressure
0-5000 psi [0-300 bar]
7/16 - 20 o-ring fitting
L1,L2
Case pressure
0-100 psi [0-10 bar]
7/8 - 14 o-ring fitting
X1
Load Sense signal
0-5000 psi [0-300 bar]
7/16 - 20 o-ring fitting (tee into Load Sense signal line)