Out of usable range message, Ums sensor not calibrated message, Ums sensor faulted message – JLG 800A_AJ ANSI Service Manual User Manual
Page 279: Incompatible software detected message, Calibration faults
![background image](/manuals/551633/279/background.png)
SECTION 4 - BOOM & PLATFORM
3120740
– JLG Lift –
4-65
Out of Usable Range Message
8/1 UMS SENSOR OUT OF USABLE RANGE
When both the Chassis tilt sensor and the UMS sensor
read greater than 10 in the same direction the UMS will
be disengaged until the condition no longer exists and a
fault shall be raised.
Solution:
• Verify the message clears when operating the machine
on grade less than 10.
• Inspect sensor mounting.
• Verify sensor calibration on level pad.
UMS Sensor Not Calibrated Message
8/1 UMS SENSOR NOT CALIBRATED
If the control system detects a sensor out of range condi-
tion or a not calibrated fault with the UMS angle sensor,
the control system shall report a fault and disable Tower
Lift Down and activate the ground boom malfunction indi-
cator lamp, upright tilted lamp and platform alarm continu-
ally
If the control system detects that the UMS angle sensor
has not been calibrated, the ground boom malfunction
lamp will flash at a 3 Hz rate until the system is calibrated
or disabled.
Solution:
• Calibrate sensor.
UMS Sensor Faulted Message
8/1 UMS SENSOR FAULTED
If the system detects that the UMS sensor frequency out-
side the 100Hz +/- 5Hz range or the duty cycle is outside
50% +/- 21% range the control system shall report a fault.
Solution:
• Inspect wire harness going to the sensor and UMS
module.
• Inspect sensor mounting.
• Replace sensor.
Incompatible Software Detected Message
9/9 INCOMPATIBLE SOFTWARE DETECTED
If the control system detects that the ground module soft-
ware is incompatible with the UMS module, the UMS mod-
ule shall report a fault and disable the footswitch signal to
the ground module.
Solution:
• Update ground module software.
Calibration Faults
CAL FAILED-CHASSIS NOT LEVEL
The control system shall display a fault in the event the
raw sensor output is greater than 5° for the chassis sen-
sor.
CAL FAILED-UMS SENSOR RAW OUTPUT OUT OF
RANGE
The control system shall display a fault in the event the
raw sensor output is greater then 5° for the UMS sensor.
CAL FAILED-CALIBRATION DISRUPTED
If calibration is disrupted, the control system shall display
this fault.
C A L FA I L E D - U M S S E N S O R M OV E M E N T N O T
DETECTED
The UMS angle has not detected the required amount of
movement during calibration.