Chapter 7 – Prestart Inspection

TB65J – 0084248

35

Test Button

Reset Button

Figure 7.22 – Wiring Box

Some machines may have an electrical outlet at the plat-

form, but no power-input connector on the wiring box. In

that case, power is supplied by an optional AC generator.

An external power source is not required.

With the engine running, place the machine/generator

switch on the front of the upper control panel in the gen-

erator position to provide electrical power to the electrical

outlet at the platform and to the outlet on the end of the

generator housing.

Plug an electrical tool into the receptacle at the platform

and at the generator and try to operate the tool to verify

proper operation of the outlet.

The outlet is equipped with a ground fault circuit inter-

rupter (GFCI). Use the following procedure to test the

GFCI.

. Push the test button (refer to Figure 7.23).

Figure 7.23 – Electrical Power Outlet

2. Plug an electrical tool into the outlet and verify the

power is off.

• If the power was off, push the reset button to

restore power.

• If the power was on, repair or replace the recep-

tacle.

Platform Control Cover

The machine may be equipped with an optional platform

control cover. Inspect the cover to ensure it fits properly

over the control panel.

Drive Motion Alarm

The machine may be equipped with an optional drive

motion alarm. Drive in both the forward and reverse direc-

tions to ensure that the alarm sounds to warn personnel

in the area that the aerial platform is in motion.

Flashing Light

The machine may be equipped with an optional flashing

light mounted to the top of the counterweight.

To inspect the flashing light:

. Turn the battery disconnect, pull the emergency stop

button outward at the lower controls, and turn the start

switch on.

2. Visually check to see that the light is flashing ap-

proximately one flash per second.

Note

There is not an off switch for the flashing light. The light

cannot be turned off while the start switch is in the on

position.

Sandblast Protection Kit

The optional sandblast protection kit protects the cylinders

from abrasion while sandblasting or from paint overspray.

Rubber covers protect each cylinder rod as it extends

and retracts. The covers prevent sand and paint from

damaging the cylinder seals and rod.

Inspect the covers while operating the machine to ensure

they are securely fastened and completely cover the cyl-

inder rod. Make sure there are no holes in the covers.

Driving and Work Lights

The machine may be equipped with driving lights and/or

platform work lights. Turn the engine on and use the

switch on the back of each light to momentarily turn it on

to see that it works.

Platform Glazier Package

Inspect the glazier trays (refer to Figure 7.24) and keeper

pins to make sure they are in good condition and are not

bent or distorted. The straps and padding must be in good

condition and not worn, cut or frayed.

Power-Input