Danger, Warning – Snorkel TB65J User Manual
Page 38

Chapter 7 – Prestart Inspection
34
TB65J – 0084248
3. At the upper controls (refer to Figure 7.2), pull the
emergency stop button outward.
Figure 7.21 – Upper Controls
4. Turn the start switch on the front of the upper control
panel to start until the engine starts, then release it.
Note
If the machine has a GM engine, there will be a 7 to 10
second delay after starting the engine, before the throttle
will go to mid or high. Start the engine and wait 10 seconds
before proceeding with machine operation.
5. Let the engine warm to operating temperature.
Danger
Pinch points may exist between moving components.
Death or serious injury will result from becoming
trapped between components, buildings, structures,
or other obstacles. Make sure all personnel stand
clear of the aerial platform while performing the pre-
start inspection.
Warning
The potential for an accident increases when operat-
ing an aerial platform that is damaged or malfunction-
ing. Death or serious injury could result from such
accidents. Do not operate the aerial platform if it is
damaged or malfunctioning.
6. Test the platform foot switch by moving a boom
function control without stepping on the foot switch.
If movement occurs the interlock is not functioning
properly. Do not operate the machine until the prob-
lem is corrected.
7. Test the operation of each control in both directions
from the upper controls.
8. The drive range switch and maximum travel speeds
are interlocked through a limit switch on the main
boom that senses the position of the booms.
• When the main boom is raised a few degrees above
horizontal or extended approximately 6½″ (6.5
cm), the machine should travel in low speed only.
• To operate in high speed the booms must be
stowed.
Emergency Stop
To test the emergency stop button from the upper
controls:
. At the lower controls, start the engine and place the
control selector switch in the upper control position.
2. At the upper controls, push the emergency stop but-
ton inward to turn off electrical power.
3. Verify that the engine shuts off and the upper control
functions do not operate.
Emergency Power
To test the emergency power system from the upper
controls:
. Turn the battery disconnect switch on.
2. At the lower controls, pull the emergency stop button
outward and place the start switch in the on position.
Place the control selector switch in the upper control
position.
3. At the upper controls (refer to Figure 7.4), pull the
emergency stop button outward and place the start
switch in the on position.
4. Hold the engine/emergency power switch in the
emergency power position and step on the platform
foot switch to verify operation of the aerial platform
using the emergency power system.
All Motion Alarm
The machine is equipped with an all motion alarm.
• Operate machine functions to ensure that the alarm
sounds to warn personnel in the area that the aerial
platform is in motion.
Horn Button
The machine may be equipped with an optional horn.
Press the horn button on the right side of the upper
control panel to ensure that it sounds to warn personnel
in the area.
Electrical Power Outlet
Connect a source of 0 volt AC power to the power-
input connector on the left side of the wiring box (refer
to Figure 7.22).
Engine/Emergency
Power Switch
Emergency
Stop Button
Horn Switch
Start Switch