Chapter 7 – Prestart Inspection

34

TB65J – 0084248

3. At the upper controls (refer to Figure 7.2), pull the

emergency stop button outward.

Figure 7.21 – Upper Controls

4. Turn the start switch on the front of the upper control

panel to start until the engine starts, then release it.

Note

If the machine has a GM engine, there will be a 7 to 10

second delay after starting the engine, before the throttle

will go to mid or high. Start the engine and wait 10 seconds

before proceeding with machine operation.

5. Let the engine warm to operating temperature.

Danger

Pinch points may exist between moving components.

Death or serious injury will result from becoming

trapped between components, buildings, structures,

or other obstacles. Make sure all personnel stand

clear of the aerial platform while performing the pre-

start inspection.

Warning

The potential for an accident increases when operat-

ing an aerial platform that is damaged or malfunction-

ing. Death or serious injury could result from such

accidents. Do not operate the aerial platform if it is

damaged or malfunctioning.

6. Test the platform foot switch by moving a boom

function control without stepping on the foot switch.

If movement occurs the interlock is not functioning

properly. Do not operate the machine until the prob-

lem is corrected.

7. Test the operation of each control in both directions

from the upper controls.

8. The drive range switch and maximum travel speeds

are interlocked through a limit switch on the main

boom that senses the position of the booms.

• When the main boom is raised a few degrees above

horizontal or extended approximately 6½″ (6.5

cm), the machine should travel in low speed only.

• To operate in high speed the booms must be

stowed.

Emergency Stop

To test the emergency stop button from the upper

controls:

. At the lower controls, start the engine and place the

control selector switch in the upper control position.

2. At the upper controls, push the emergency stop but-

ton inward to turn off electrical power.

3. Verify that the engine shuts off and the upper control

functions do not operate.

Emergency Power

To test the emergency power system from the upper

controls:

. Turn the battery disconnect switch on.

2. At the lower controls, pull the emergency stop button

outward and place the start switch in the on position.

Place the control selector switch in the upper control

position.

3. At the upper controls (refer to Figure 7.4), pull the

emergency stop button outward and place the start

switch in the on position.

4. Hold the engine/emergency power switch in the

emergency power position and step on the platform

foot switch to verify operation of the aerial platform

using the emergency power system.

All Motion Alarm

The machine is equipped with an all motion alarm.

• Operate machine functions to ensure that the alarm

sounds to warn personnel in the area that the aerial

platform is in motion.

Horn Button

The machine may be equipped with an optional horn.

Press the horn button on the right side of the upper

control panel to ensure that it sounds to warn personnel

in the area.

Electrical Power Outlet

Connect a source of 0 volt AC power to the power-

input connector on the left side of the wiring box (refer

to Figure 7.22).

Engine/Emergency

Power Switch

Emergency

Stop Button

Horn Switch

Start Switch