Chapter 6 – controls danger, Caution – Snorkel TB65J User Manual
Page 21

TB65J – 0084248
7
• Start switch
• Emergency stop button
• Controls selector switch
• Ground operation switch
• Rotation switch
• Boom elevation switch
• Boom extension switch
• Boom speed knob
• Jib articulation switch
• Platform level switch
• Platform rotation switch
• Engine/Emergency power switch
• Engine speed switch
• Fuel switch (dual fuel machines)
• Manifold air inlet heater (option for Deutz engines)
• Hydraulic system warm-up switch (option)
Start Switch
The start switch (refer to Figure 6.2) works like an auto-
mobile ignition switch.
• Hold the switch in the start position until the engine
starts, then release it to on.
• If the engine dies, the switch must be turned to off
before it can be turned back to start.
An alarm sounds, when the switch is turned on, to warn
others that the machine engine is being started.
Note
On some machines it may be necessary to pause about
three seconds in the on position before going to start so
the starter can engage.
If the platform is to stay in a particular position for a long
time, turn the start switch to off to shut off the engine and
save fuel.
Emergency Stop Button
The emergency stop (refer to Figure 6.2) is a two-posi-
tion, red push button.
• Push the button inward to disconnect power to all
control circuits.
• Pull the button outward to restore power.
Controls Selector Switch
Use the controls switch (refer to Figure 6.2) to select
between lower control and upper control operation.
• Place the switch in the upward position to operate
the aerial platform from the upper controls.
• Place the switch in the downward position for lower
control operation.
Chapter 6 – Controls
Danger
Pinch points may exist between moving components.
Death or serious injury will result from becoming
trapped between components, buildings, structures,
or other obstacles. Make sure all personnel stand
clear while operating the aerial platform.
• Controls to position the platform are located on the
lower control panel on the turntable and on the upper
control panel in the platform.
• Controls to drive the aerial platform are located on
the upper control panel only.
Battery Disconnect Switch
The battery disconnect is located behind the door on
the left rear of the turntable above the batteries (refer to
Figure 6.).
Figure 6.1 – Battery Disconnect Switch
The battery disconnect removes electrical power from all
electrically controlled functions when in the off position.
• Place the switch in the on position to electrically con-
nect the battery to the electrical system.
Caution
Only authorized personnel should operate the aerial
platform. Unqualified personnel may cause injury
to coworkers or property damage. Lock the battery
disconnect switch in the off position before leaving
the aerial platform unattended.
• Lock the battery disconnect switch in the off position
to prevent unauthorized use of the aerial platform.
Lower Controls
The lower controls (refer to Figure 6.2) are located on the
left side of the turntable. Boom and platform functions
can be operated from the lower controls. The following
are located on the lower control panel:
Battery Disconnect Switch