beautypg.com

Chapter 12 – troubleshooting – Snorkel S2633 User Manual

Page 49

background image

S2633 – 8210048

45

Chapter 12 – Troubleshooting

The troubleshooting chart may be used to locate and

eliminate situations where machine operation may be

interrupted. If the problem cannot be corrected with the

action listed, stow the machine and remove it from ser-

vice. Repairs must be made by qualifi ed maintenance

personnel.

Troubleshooting Chart

Symptom

Possible Cause

Corrective Action

All functions stop working.

Motor or pump failure.

Manually stow the machine using the

emergency lowering knob.

Low fl uid level in reservoir.

Check hydraulic fl uid level. Add correct

type of fl uid if necessary.

Batteries discharged.

Recharge batteries.

Electrical system malfunction.

Stow the machine and do not operate until

repairs are made.

Platform will not raise or lower

from lower controls.

Enable button not depressed.

Press and hold the enable button while op-

erating the platform raise/lower switch.

Battery disconnect is unplugged.

Plug in the battery disconnect connector.

Emergency stop button is pushed

inward to the off position.

Twist the button clockwise to restore

power.

Emergency lowering knob is not prop-

erly disengaged.

Make sure the knob returns to the normal

operating position.

Platform will not raise or lower

from upper controls.

Switches set wrong.

From the upper controls:

Press the platform raise/lower button

then squeeze and hold the interlock

switch. Push the joystick forward to

raise the platform or pull it backward

to lower.

y

Battery disconnect is unplugged.

Plug in the battery disconnect connector.

Emergency lowering valve is open.

Twist the button clockwise to restore

power.

Emergency lowering knob not prop-

erly disengaged.

Ensure knob is fully released and the emer-

gency lowering valve is fully closed.

Platform will not raise and alarm

is sounding.

Machine is not on a level surface.

Lower the platform and drive to a level

surface.

Lower or upper controls do not

work.

Emergency stop button is pushed

inward to the off position.

At the upper and lower controls twist the

button clockwise to restore power.

Battery disconnect is unplugged.

Plug in the battery disconnect connector.

Battery charger plugged in.

Unplug the battery charger.

Platform will not raise, or raises

slower than normal.

Emergency lowering knob not prop-

erly disengaged.

Make sure the knob returns to the normal

operating position.

Platform capacity has been ex-

ceeded.

Remove load from platform. Refer to

platform capacity placard for maximum

capacity.

Low battery charge.

Check the battery charge indicator and

recharge the batteries if necessary.

Platform drifts down.

Emergency lowering knob not prop-

erly disengaged.

Make sure the knob returns to the normal

operating position.

Hydraulic system malfunction.

Stow the machine and do not operate until

repairs are made.

Platform will not lower.

Safety prop in place.

Rotate the safety prop counterclockwise

to the stowed position.