beautypg.com

Snorkel X33RT-sn10000+ User Manual

Page 10

background image

1. Open cabinets and inspect for

damage, fluid leaks or missing
parts.

2. Check the level of the hydraulic

fluid with the platform fully
lowered. The hydraulic reservoir is
located in the Control Cabinet.
The fluid must be above the
minimum line. Add hydraulic fluid
if necessary.

3. Check the fluid level in the starter

battery is correct.

4. Check the level of the Diesel fuel

with the engine switched off. The fuel tank is located in the Engine Cabinet. Add fuel as
required.

5. Check that all the guardrails are in place and all the fasteners are properly tightened.

6. Inspect the machine thoroughly for cracked welds and structural damage, loose or missing

hardware, hydraulic leaks, damaged control cable, loose wire connections and wheel bolts.

Page 6

Operation Manual

Pre-Operation Safety Inspection

P

RE-OPERATIONAL

S

AFETY

I

NSPECTION

NOTE: Care fully read, un der stand and fol low all safety rules, op er at ing in struc tions, la bels
and Na tional safety In struc tions/Re quire ments. per form the fol low ing steps each day be -
fore use.

Figure 3: Hydraulic Tank