Mantenimiento de rutina, Safety interlock test, Battery maintenance – Snorkel ULII40-sn15001-21372 User Manual
Page 13: Especifiacaciones, Emergency lowering, After use each day

4
EMERGENCY LOWERING
If
the
platform
should
fail
to
lo
w
er,
NEVER
climb
down
the
mast.
Ask
a
person
on
the
ground
to
open
the
Emer-
gency
Lowering
Valve
to
lower
the
platform.
This
valve
is
located
through
a
cutout
in
the
power
unit
cover
on
the
left
side
of
the
m
ast
(Figure
2).
1.
Pull
the
knob
out
and
turn
1
/
4
turn
to
open
the
Emergency
Lowering
Valve.
2.
To
close
the
Emergency
Lowering
Valve,
turn
the
knob
until
it
snaps
back
in.
Once
the
platform
is
fully
lowered,
be
certain
that
the
Emergency
Lowering
Valve
is
closed
again.
The
platform
w
ill
not
elevate
if
the
Emergency
Lowering
Valve
is
open.
AFTER USE EACH DAY
1.
Ensure
that
the
platform
is
fully
lowered.
2.
Park
the
machine
on
level
ground,
preferably
under
cover.
3.
Secure
against
vandals,
children
or
unautho-
rized
operation
by
turning
the
Key
Switch
to
OFF
and
remove
the
key.
Safety Interlock Test
NEVER
perform
this
test
from
the
platform.
1.
Properly
install
all
four
(4)
outriggers
and
level
base.
2.
Release
the
tension
on
one
(1)
outrigger
by
turning
the
screwjack
counterclockwise,
until
the
indicator
lamp
is
no
longer
lit.
3.
While
standing
on
the
ground
activate
the
control
panel
to
elevate
the
platform.
Platform
should
not
elevate
.
4.
Re-level
the
base
with
all
four
(4)
outriggers
then
repeat
step
2
with
another
outrigger.
5.
Repeat
steps
2
, 3
&
4
until
all
four
(4)
outriggers
have
been
tested.
DO
NOT
use
a
machine
that
elevates
when
the
tension
has
been
released
on
an
outrigger.
M
a-
chine
must
be
repaired
before
using.
Battery Maintenance
Hazard
of
explosive
gas
m
ixture.
Keep
sparks,
flame
and
smoking
materials
away
from
battery.
Always
w
ear
safety
glasses
when
working
with
batteries.
Battery
fluid
is
highly
corrosive.
R
inse
away
any
spilled
fluid
thoroughly
with
clean
water.
Always
replace
battery
with
UpRight
battery
or
manufacturer
approved
replacement
weighing
at
least
52
lbs.
(23.6
kg)
each.
Check
battery
fluid
level
daily,
especially
if
work
platform
is
being
used
in
a
warm,
dry
climate.
If
electrolyte
level
is
less
than
3
/
8
in.
(10
mm)
above
plates
add
distilled
water
only.
D
O
NOT
use
tap
water
with
high
mineral
content,
it
will
shorten
battery
life.
Keep
terminals
and
tops
of
batteries
clean.
Refer
to
the
Service
Manual
to
extend
battery
life
and
for
complete
service
instructions.
29
Especifiacaciones*
ÍTEM
UL25
UL32
UL40
Altura
plataforma
Máximo
7,62 m (25 pies)
9,75 m (32 pies)
12,19
m
(40
pies)
Mínimo
38
,00
cm
(15 plg)
38,00 cm (15 plg)
38,00 cm (15 plg)
Capacidad
plataforma
159 kg (350 lb)
136 kg (300 lb)
136 kg (300 lb)
Dimensiones
guardada
Alto
1,98 m (78 plg)
2,44 m (96 plg)
2,84 m (112 plg)
Ancho
74
cm
(29 plg)
74 cm (29 plg)
74 cm (29 plg)
Largo
1,2
4 m
(4
9 p
lg
)
1,2
4 m
(4
9 p
lg
)
1,2
4 m
(4
9 p
lg
)
Altura
diagonal
guardada
-
1,98
m
(78
plg)
1,98 m (78 plg)
Largo
diagonal
guardada
-
2,53
m
(99,5
plg)
2,90 m (114 plg)
Descansos
(estabilizadores
extendidos)
Ancho
1,5
0 m
(
59
p
lg
)
2,0
6 m
(8
1 p
lg
)
2,3
4 m
(9
2 p
lg
)
Largo
1,4
2 m
(5
6 p
lg
)
1,9
8 m
(7
8 p
lg
)
2,2
6 m
(8
9 p
lg
)
Peso
total
345 kg (760 lb)
390 kg (860 lb)
422 kg (930 lb)
Sin
estabilizadores
ni
gatos
324 kg (714 lb)
366 kg (806 lb)
392 kg (864 lb)
Estabilizadores
y
gatos
21
kg
(46
lb)
25
kg
(54
lb)
30
kg
(66
lb)
Peso
opción
CC
29
kg
(64
lb)
29
kg
(64
lb)
29
kg
(64
lb)
Altura
baranda
1,10
m
(43,5
plg)
1,10
m
(43,5
plg)
1,10
m
(43,5
plg)
Altura
barra
punta
pie
152
mm
(6
plg)
152
mm
(6
plg)
152
mm
(6
plg)
Voltaje
sistema,
máximo
CA
motor
eléctrico
120
volts,
corriente
alterna,
60
Hz
o 220
volts,
corriente
alterna,
50/60
Hz
Fuente
de
electricidad
CC
1
batería
de
12
volts,
grupo
27
105
Amp/hr.
Peso
mín.
23,60
kg
(52
lb)
Cargador
de
batería
Automático,
120
volts,
corriente
alterna,
60
Hz
o 220
volts,
corriente
alterna,
50
Hz.
Alimenta
10
amp,
12
volts,
corriente
continua
Presión
máxima
sistema
hidráulico
165
bar
(2400
lb/plg
2
)
Mantenimiento de rutina
Use
la
siguiente
tabla
como
guía
para
mantenimiento
de
rutina.
Consulte
en
el
Manual
de
m
antenimiento
las
instrucciones
de
mantenimiento
completas.
OPERACIÓN
DE
MANTENIMIENTO
INTERVALO
MENSUAL
C/3
MESES
ANUAL
DIARIO
O
O
O
50
HR
125 HR
500 HR
Verifique
precisión
del
nivel
circular
X
Verifique
funcionamiento
de
enganches
de
estabilizadores
X
Verifique
nivel
de
electrólito
y
cargue
batería
( sólo
modelos
CC)
X
Reemplace
etiquetas
dañadas
o
perdidas
X
Inspeccione
condición
del
cable
de
control
X
Cerciórese
que
el
mástil
no
esté
torcido,
no
tenga
grietas
ni
remaches
sueltos
X
Revise
la
operación
del
botón
de
paradas
de
emergencia
del
chasis
y
de
la
plataforma
X
Revise
la
operación
de
la
válvula
de
bajada
de
emergencia
X
Cerciórese
que
las
ruedas
no
estén
dañadas
X
Verifique
el
nivel
del
fluido
hidráulico
X
Verifique
el
par
de
torsión
de
los
pernos
de
la
jaula
y
su
soporte
X
Inspeccione
y
ajuste
la
correa
de
secuencia
X
Lubrique
cadenas
y
poleas
de
levante
X
Cambie
fluido
hidráulico
(ISO
N
o
46)
X
*
Especificaciones
pueden
cambiarse
sin
aviso
previo.