beautypg.com

Gauge configuration – AEM 30-4900 Wideband Failsafe Gauge User Manual

Page 8

background image

Page 9

Gauge Configuration


In this tab, the gauge lighting and display features can be configured.

Display Option

Option

Description

Center

Display

Center display reading configuration; use to select either pressure (InHg / PSIg or Bar) or O2 sensor
(AFR or Lambda)

Installed

Faceplate

Faceplate configuration; use to match 24 outer LEDs to faceplate with either Pressure (InHg / PSIg
or Bar) or O2 sensor (AFR or Lambda) [See Appendix II – Changing Faceplate / Bezel]

Alarm Flash

Option

Description

Flash Speed

Select speed of flashing while alarm is triggered; flash slow or fast

Dimmer Max Brightness

Option

Description

Dimmer Max

Brightness

Select whether +12V or ground indicates maximum backlighting brightness

Bar-Graph LED Color

Option

Description

RED LED (1)

Can be disabled; use slider to configure multiple LEDs. Reference gauge display at bottom right.

ORG LED (2)

Can be disabled; use slider to configure multiple LEDs. Reference gauge display at bottom right.

GRN LED (3)

Cannot be disabled; use slider to configure multiple LEDs. Reference gauge display at bottom right.

ORG LED (4)

Can be disabled; use slider to configure multiple LEDs. Reference gauge display at bottom right.

RED LED (5)