Fast & Fluid Ferraris Automatic Mixer User Manual
Page 30
FAST & FLUID MANAGEMENT srl
A Unit of Idex Corporation
1155432A-it,en,de.doc – 11/09/2006
30
MAINTENANCE AND CLEANING
For any maintenance operation or inspection use protective gloves and switch off the mixer Ferraris.
Only trained personal can execute maintenance operations
Periodical maintenance list
Maintenance frequency
Operations
7 days
1 month
6 months
1 year
2 years
Check of the security elements
YES
Outside cleaning
YES
Inside cleaning
YES
Lubrication vertical guides
YES
Lubrication screws and shaft
YES
Cleaning and lubrication of the
Crown gear
YES
Lubrication conical triad
YES
Lubrication blocking screws wheel
YES
Lubrication unblocking lever and trolley
shafts
YES
Check of the rubber disks
YES
Check of the belts
YES
Check of the security elements
BLOCKING DOOR/SHUTTER ( with switched off machine and closed door/shutter )
Pulling the handle , the door/shutter hasn’t to open.
DOOR/SHUTTER (The machine is switched on but it doesn’t work; Connected plug and turn the switch on “I”)
When the machine is switched on
attend some seconds for the release of the door/shutter
Open the door/shutter
Pushing or or , the machine hasn’t to work , but it has to indicate an error (E-1).
Pushing the opening and closing keys of the plates or , the machine hasn’t to work , but it has to
indicate an error (E-1
).
EMERGENCY PUSH BUTTON (Working machine)
Switch on the machine.
Open the door/shutter and
insert an empty can as
indicated in the specific
chapter. Then close the
door/shutter.
Push or or
to start the machine.
Before the cycle ends, push
the red emergency push
button.
The rotation has to stop
while the machine indicate an
error (E-0).
The cradle stops with the
closed plates and no key
has to work.
Set the emergency push
button turning it in clock
wise direction.
Push all the keys except from
the key STOP. No key should
be operational.
Push the key STOP
and verify that the cradle
position to permit to the plates
to open.
Verify that the door/shutter is
unlocked.