TROUBLESHOOTING

It is possible to display error using Operator Panel (optional)

“E-0” ERROR 0
- Emergency push button – pushed down

1. Turn the emergency push button clockwise

2. Check the wires connection on the emergency

push button

3. Defective emergency push button wire/cable

4. Defective Logic Board

“E-1” ERROR 1
- Open door/shutter

1. Close the door/shutter

2. Microswitch bracket out of position (assembled on the

door/shutter)

3. Broken microswitch

4. Defective wire/cable of the microswitch

5. Defective Logic Board

“E-3” ERROR 3
-a) Distance between can and superior plate

not sufficient

-b) Loosen/broken belt for closing plates
-c) Damaged/broken sensor for closing (on

optic sensor board)

1a. Increase the distance pressing the key STOP before

beginning the stirring cycle.

1b. Regulate the belt or replace it.

1c. Clean the sensor on the Optic Sensor Board

2. Defective cable between Logic Board and Optic Sensor Board

3. Defective Optic Sensor Board

E-4” ERROR 4
- Wrong position of the mixing apparatus

1. Before starting the mixing cycle push the “STOP” key

“E-5” ERROR 5
- Actuator faulty position

1.Broken actuator switch

2.Broken actuator

3. Defective cable of the micro switch.

4. Defective Logic Board

“E-6” ERROR 6
- Unable to find loading position

1. Switch off the machine for 15 minutes. If the error appears

again call for assistance in replacing the broken micro switch

of the actuator

2. Clean or replace the sensor of zero position

3. Defective Optic Sensor Board

“E-8” ERROR 8
- The emergency push button is pressed

during the functioning

1. If during the mixing cycle the emergency push button is

pressed , push STOP to restart the machine.

“E-9” ERROR 9
- Anomaly of the inverter

1. Power supply too low or not stabilized

2. Extension cord is used.

3. Switch off the machine for 3-5 seconds and then switch it

again. If the problem persist call for assistance.