USER OPERATION AND MAINTENANCE

HP SERIES

PORTABLE PUMPS

37

7. Reinstall pre-cleaner and retainer

ring on cartridge.

8. Reinstall foam pre-cleaner,

cartridge and retainer plate

assembly in air cleaner housing on

top of engine. Secure in place with

nut.

9. Reinstall air cleaner cover on top

of pump and latch in place.

WARNING: DO NOT run engine
with air cleaner or air cleaner
cover removed.

10. Reconnect negative battery

cable and close pump cover as

necessary.

CLEAN COOLING SYSTEM

If the pump is operated in an area

where there is loose debris such as grass,

papers, leaves or dirt the rotating screen

and the air cooling system may become

clogged after prolonged service. After

every 100 hours of operation or yearly

remove the pump covers and blower

housing and clean the areas shown in

the illustration to prevent engine

damage caused by overheating and/or

over-speeding. Clean more often if

necessary.

CLEAN DEBRIS GUARD

If the pump is operated in a dry area

where there is loose debris such as grass,

papers, leaves or dirt this debris must be

removed from the debris guard daily or

more often if needed to prevent engine

damage caused by overheating and/or

over-speeding.

CAUTION: For proper engine
operation, keep controls and
linkages clean and free of
debris.

CAUTION: Periodically clean
muffler area to remove all
grass, paper, leaves, dirt or
other combustible debris.

CLEAN SPARK ARRESTER SCREEN

The engine muffler is equipped with a

spark arrester screen assembly. Remove