Initial checkout procedures – Hale HP Series User Manual
Page 18
HP SERIES
PORTABLE PUMPS
USER OPERATION AND MAINTENANCE
18
Upon receipt of the pump from the
factory remove the pump and all
accessories from the shipping container
and check for damage. Note the serial
number of the pump located on the
engine air shroud near the recoil starter
pull handle. Record this number on the
warranty registration card located at
the back of this manual and return
warranty registration.
PORTABLE PUMP BATTERY ACTIVATION
After unpacking all pump components
open the top cover on the pump and
remove the battery from its holder. The
battery is a dry charged battery and is
shipped dry. Remove the covers from
each cell of the battery and fill each
cell with electrolyte. Replace the covers
on each cell and tighten. Return the
battery to its holder and clamp in place.
CAUTION: Always connect
the black wire to the negative
battery terminal last.
Connect the red cable to the positive
(+) terminal and connect the black
cable to the negative (-) terminal.
Make sure that the plastic overflow tube
on the battery is directed down to the
lowest point of the pump.
"X" SERIES PUMP INSTALLATION
1. After unpacking all pump
components remove the mounting bolts
and shock absorbing feet from the four
corners of the pump. Retain these bolts
and feet for securing the pump during
installation.
2. To assist in pump mounting a
mounting dimension drawing is included
at the back of this manual. Mark
location of the mounting holes in
accordance with this drawing.
3. Drill 9.5 mm (3/8 inch) diameter holes
at the four corners of the pump to insert
the bolts to hold the pump in place.
Place pump at proper location on the
apparatus making sure the shock
absorbing feet are under each corner.
INITIAL CHECKOUT PROCEDURES
4
PORTABLE PUMP BATTERY
POS BATTERY
TERMINAL
NEG BATTERY
TERMINAL
CELL CAPS