beautypg.com

Hp series portable pumps – Hale HP Series User Manual

Page 30

background image

HP SERIES
PORTABLE PUMPS

USER OPERATION AND MAINTENANCE

30

6. Remove oil level plug from

gearbox.

7. Place funnel in oil fill fitting and

slowly pour oil into gearbox until oil

starts to flow from the oil level hole.

8. Replace oil level plug, oil fill fitting

and vent.

9. Return pump to storage or

operation.

EXHAUST PRIMER MAINTENANCE

The exhaust primer should be cleaned

after every 100 hours of operation or

when priming of the pump appears

sluggish. The following procedures shall

be used to clean the exhaust primer.

5. Replace oil fill fitting and vent.

6. Return pump to storage or

operation.

CHANGE GEARBOX OIL (HP100)

The oil in the gearbox of the HP100

should be changed after every 50 hours

of operation. The following procedures

shall be used to change the gearbox oil.

1. Place pump on clean level work

surface and gain access to the

pump gearbox.

2. Place container under oil drain

plug to catch waste oil.

3. Using a wrench remove oil drain

plug.

NOTE: The oil may not flow
freely from the gear case at
first. To facilitate oil flow
remove oil fill fitting.

4. Replace oil drain plug after all oil

has drained from the gearbox.

NOTE: Dispose of waste oil in
accordance with local
ordinances.

5. Obtain proper grade of oil (SAE

30).

EXHAUST PRIMER

TUBING

EXHAUST PRIMER

ASSEMBLY

EXHAUST PRIMER

CABLE

EXHAUST PRIMER

BOLTS