The HP Series portable pumps are

designed to provide years of reliable

service with a minimum of maintenance

on the pump end. The pump must be

cleaned and flushed out after each use.

Failure to clean and flush the pump may

degrade pump performance. The only

maintenance that is usually required on

a regular basis is to hydrostatically test

the pump each year.

LEAK TEST

A leak test of the pump must be

performed each year. The leak test will

be conducted at the pump working

pressure.

WARNING: TO PREVENT
ACCIDENTAL STARTING
when
servicing the engine or pump
always disconnect the
negative wire from battery
terminal.

CHECK OIL LEVEL (HP100 GEARBOX)

The HP100 pump has a gearbox that

requires routine maintenance. The oil

should be checked in the gearbox every

eight hours of operation and after each

use of the pump. The following

procedures are used to check the oil

level in the HP100 gearbox.

1. Place pump on a level work

surface to gain access to the

gearbox.

2. Locate the oil fill fitting, the oil level

plug and the oil drain plug on the

pump gearbox.

3. Loosen oil level plug with wrench

and begin to remove slowly. If the oil

is at the proper level there should be

a slight trickle of oil from around the

plug.

4. Replace plug and tighten. If oil

needs refilling remove oil fill fitting,

vent and oil level plug. Add new

gear oil (SAE 30) through oil fill fitting

until oil starts to flow from oil level

plug. Replace and tighten oil level

plug.

8

PUMP MAINTENANCE

OIL DRAIN PLUG

OIL FILL FITTING

OIL LEVEL PLUG