Hp series portable pumps – Hale HP Series User Manual
Page 36
HP SERIES
PORTABLE PUMPS
USER OPERATION AND MAINTENANCE
36
cartridge air dry thoroughly before
using.
CAUTION: Petroleum solvents,
such as kerosene, are not to
be used to clean cartridge.
They may cause deterioration
of the cartridge. DO NOT OIL
CARTRIDGE. DO NOT USE
PRESSURIZED AIR TO CLEAN OR
DRY CARTRIDGE
3. Remove nut holding retainer
plate, cartridge and foam pre-
cleaner to top of engine.
4. Remove retainer plate and foam
pre-cleaner from cartridge.
5. Service foam pre-cleaner:
a. Wash in liquid detergent and
water.
b. Squeeze dry in a clean cloth.
c. Saturate in engine oil. Squeeze
in clean, absorbent cloth to remove
all excess oil.
6. Service cartridge:
a. Clean by tapping gently on flat
surface.
b. If very dirty, replace, or wash in
a low or non-sudsing detergent and
warm water solution. Rinse
thoroughly with flowing water from
mesh side until water runs clear. Let
AIR CLEANER
HOUSING
FOAM
PRE-CLEANER
AIR CLEANER
COVER
RETAINER PLATE
NUT
AIR FILTER COMPONENTS
CARTRIDGE
AIR CLEANER COVER
AIR CLEANER
COVER LATCH
AIR FILTER COVER REMOVAL