For the "I" version, turn the key switch

and release when the pump has started.

6. PRIME PUMP: Hold priming lever (

)

down to prime the pump and establish

suction. Monitor suction and discharge

gauges to determine when suction is

established. Once suction is established

release the priming lever and make sure

the lever returns to the up position.

CAUTION: Do not run pump
for more than 45 seconds
without suction established.

NOTE: When the pump is
connected to a positive
pressure source priming is not
required. When using the
pump with a positive pressure
connected to the inlet ensure
the 1/4 turn valve on the
exhaust primer assembly is in
the closed position prior to
starting the pump.

7. ESTABLISH DISCHARGE: Once suction

is established as indicated by the

gauges, open the pump discharge

valve by rotating handle

counterclockwise.

8. ADJUST THROTTLE: Adjust throttle lever

to obtain the desired discharge pressure

on the discharge gauge.

CAUTION: Exhaust system
components may smoke
during the initial break-in
period. This smoking will stop
after the pump is run several
times.

COLD WEATHER STARTING HINTS

1. Be sure to use the proper oil for the

temperature expected.

2. Set speed control at part-throttle

position.

3. A warm battery has much more

starting capacity than a cold battery.

4. Use fresh winter grade fuel.

NOTE: Winter grade gasoline