3. The oil drain fitting is a hex fitting

with a pipe plug. Use adjustable

wrench to hold hex fitting while

removing the pipe plug with an allen

wrench.

4. Once all oil is drained from the

crankcase replace pipe plug in oil

drain fitting and tighten with allen

wrench.

NOTE: Dispose of waste oil in
accordance with local
ordinances.

5. Remove oil fill cap on valve cover

or dipstick and place on a clean

surface.

6. Using a funnel to prevent spills, refill

crankcase with the proper grade of

oil.

NOTE: The engine will require
a minimum of 3 pints (1.4 liters)
if the oil filter is not replaced
and 3.5 pints (1.6 liters) if the oil
filter is replaced.

7. Check oil level and replace

dipstick or oil fill cap.

8. Reconnect negative battery

cable. Start pump and run for 30

seconds. Shut down the pump and

Change oil using the following