22

pump into operation for the
first time fill gearbox to proper
level with SAE 30 Weight
Detergent oil.

4. FILL HP100 GEAR BOX WITH OIL: The

HP100 is shipped without oil in the gear

box. Add oil to proper level in

accordance with procedures listed in

section 8. Replace oil level plug.

5. CONNECT SUCTION HOSE: Ensure the

hose connections are tightened with a

spanner and a strainer is placed at the

end of the hose to prevent debris from

entering the pump and causing

irreparable damage. Place end of

suction hose in water source. Make sure

the end of the suction hose does not

become submerged in the mud or silt on

the bottom. Also make sure the suction

hose has no bends or loops that are

higher than the suction connection of

the pump that would trap air and

prevent priming of the pump.

engine crankcase. Before
placing pump into operation
for the first time fill engine
crankcase to proper level with
SAE 30 Weight Detergent oil.

3. FILL ENGINE WITH OIL: When received

the engine crankcase doesnot contain

oil. Remove oil dipstick or cap on valve

cover and fill with 3.5 pints of SAE 30 Oil.

Check oil level by removing the oil

dipstick and wiping oil from dipstick with

clean cloth. Screw dipstick firmly into

place until cap bottoms on tube.

Remove to check oil level. If necessary

add additional oil to bring oil up to the

proper level. Dipstick assembly must be

firmly assembled into tube when engine

is operating .

CAUTION: The HP100 is
shipped without oil in the
gearbox. Before placing

OIL FILL CAP

OIL DIPSTICK

OIL DRAIN PLUG

OIL FILL FITTING

OIL LEVEL PLUG