beautypg.com

Shutdown and storage procedures – Hale HP Series User Manual

Page 26

background image

HP SERIES
PORTABLE PUMPS

USER OPERATION AND MAINTENANCE

26

6

SHUTDOWN AND STORAGE PROCEDURES

To enhance pump life the following

procedures shall be used when shutting

down the pump.

1. SLOW ENGINE: Move throttle lever to

the slow (

) position.

2. SECURE DISCHARGE: Close pump

discharge valve by rotating handle

clockwise.

3. SECURE ELECTRICAL POWER: Turn

master switch to the off () position.

NOTE: Do not choke
carburetor to stop the engine.
Fire may result if choke is used
to stop engine.

Prior to placing the pump in storage

after each use the following must be

accomplished. This procedure is

extremely important if the pump has

been run in salt water or freezing

conditions will be encountered.

1. MAKE HOSE CONNECTIONS: Connect

suction hose and place end in a CLEAN

WATER source. Then connect discharge

hose and prepare to operate pump.

2. ENERGIZE PUMP: Start engine and

establish water flow through pump.

3. FLUSH PUMP: Run pump for 2 minutes

to ensure clean water has circulated

through the pump.

4. DE-ENERGIZE PUMP: After water has

circulated through the pump for 2

minutes turn the master switch to the off

position.

5. UNDO HOSE CONNECTIONS:

Disconnect suction hose and discharge

hose. Drain hoses and place in proper

storage area

6. DRAIN PUMP: Open drain valves and

allow all water to drain from the pump

b o d y .

7. CLOSE VALVES: Once all water is

drained from the pump close the

discharge valve and drain valve.

8. CHECK FLUID LEVELS: Check oil level

and fuel level and refill as necessary.

9. CLEAN PUMP: Clean any debris from

the outside of the engine and pump.