5 air cleaner element, 6 compressor belt tension adjustment, General – Hale CAFSPro User Manual
Page 56: Figure 7-2: removing the belt guard, Remove belt guard

❑ Routine Maintenance
56
CAFSPro User Operation Manual
p/n: 029-0020-75-0
1.
The stainless steel mesh basket pulls out for cleaning.
2.
Clean thoroughly using warm water. Replace if the screen is ripped or
damaged. Order Hale p/n: 010-0670-00-0.
7.5
AIR CLEANER ELEMENT
Change the air cleaner element on the CAFSPro System every time the
engine air filter is changed. Order Hale p/n: 010-0690-00-0.
7.6
COMPRESSOR BELT TENSION ADJUSTMENT
(See Figure 7-3: ‘Belt Tension Gauge’ on page 57.)
General
Proper belt tension is critical
to long equipment life. A
loose belt causes a knock or
bang as the teeth jump. An
over tightened belt overloads
the bearings and leads to
premature wear or failure.
For convenience, an adjust-
ment clearance port in the
belt guard cover is now pro-
vided. If your system
includes this feature, proceed
to heading “To Check Ten-
sion” on page 57.
If your belt guard does not
have the adjustment clear-
ance port the guard must be
removed. See heading
“Remove Belt Guard” below.
Remove Belt Guard
To expose the belt, the belt guard must be removed - 6 screws and hard-
ware. (See Figure 7-2: ‘Removing the Belt Guard.’)
Figure 7-2: Removing the Belt Guard