Master pump suction gauge, Line discharge pressure gauge, Hale foamlogix controls and indicators – Hale CAFSPro User Manual
Page 23: Control unit, Figure 3-2: hale foamlogix control unit
Controls and Indicators
❑
23
CAFSPro User Operation Manual
p/n: 029-0020-75-0
Master Pump Suction Gauge
This gauge indicates the water pressure delivered to the fire pump through
the suction connection, where provided by the apparatus builder.
Line Discharge Pressure Gauge
This gauge provides an indication of the hose line pressure on the system
discharges, where provided by the apparatus builder.
Hale FoamLogix Controls and Indicators
(See Figure 3-1: ‘Operator Panel Arrangement’ on page 21.)
The following controls and indicators on the operator panel permit operation
of the Hale FoamLogix Foam Proportioning System and for monitoring foam
system operation.
Control Unit
(See Figure 3-2: “Hale FoamLogix Control Unit.”)
The control unit provides a single con-
trol point for the Hale FoamLogix
Foam Proportioning System. The red
POWER button turns the Hale Foam-
Logix system ON and places it into
the STANDBY mode.
With the FoamLogix system ener-
gized, as indicated by the left most
LED on the bar graph, foam concen-
trate injection begins when a foam
capable discharge is opened.
Other buttons on the control unit per-
mit selection of display modes to
monitor various functions, such as:
❑
WATER FLOW
❑
% FOAM
❑
TOTAL WATER FLOWED (since last reset)
❑
TOTAL FOAM FLOWED (since last reset)
Figure 3-2: Hale FoamLogix
Control Unit