313a – Bryant 313AAV User Manual
Page 54

54
11
NO PREVIOUS
C
ODE – Stored codes
a
re er
a
sed
a
fter 7
2
hours
. O
n
RED LED
bo
a
rds stored st
a
tus codes c
an
a
lso be
er
a
sed whe
n
e
v
er po
wer (
115
V or
2
4V
)
is
in
terr
upted.
Ru
n
system through
a
he
a
tin
g or cool
in
g cycle to chec
k system.
12
BLO
WER ON A
F
TER PO
WER UP –
(115
V OR
2
4V) – Nor
m
a
l oper
a
ti
o
n
.
Blo
w
er r
u
n
s f
o
r
90
seco
n
ds
,
if u
ni
t
is
po
wered up dur
in
g
a
c
a
ll f
o
r he
a
t (R-W
closed) or whe
n
(R-W ope
n
s) dur
in
g the
bl
o
w
er o
n
-del
a
y per
iod.
1
3L
IM
IT
C
IR
C
UIT LO
C
K
O
UT – Loc
kout
occurs
if the l
im
it, dr
a
ft s
a
fe
g
u
a
rd, fl
a
me
rollout, or b
loc
ke
d v
e
n
t s
w
itch*(
if used)
is
ope
n
lo
n
ger th
an
3 m
in
utes
.
C
o
n
trol w
ill
a
uto-reset
a
fter 3 hours
. See code 33.
1
4
IGNITION LO
C
K
O
UT – System f
ai
led to
ig
ni
te g
a
s
an
d pro
ve fl
a
me
in
4
a
ttempts
.
C
o
n
trol w
ill
a
uto-reset
a
fter 3 hours
.
See st
a
tus code 34.
21
GAS HEA
TING LO
C
K
O
UT –
T
u
rn
off
po
wer
an
d w
ai
t
5
m
in
utes to retr
y.
C
hec
k
f
o
r:
-
S
tuc
k closed g
a
s v
a
lv
e rel
a
y o
n
co
n
trol.
-
Mi
sw
ire or shor
t to g
a
s v
a
lv
e w
ire
.
22
ABNOR
M
AL
F
LA
M
E-PR
O
V
ING SIGNAL
F
la
me
is pro
v
ed wh
ile g
a
s v
a
lv
e
is de-
e
n
erg
ize
d
. I
n
ducer w
ill r
u
n
u
n
ti
l f
a
ult
is
cle
a
red.
C
hec
k f
or
:
-
S
tuc
k
ope
n
or le
a
ky g
a
s v
a
lv
e
.
2
3
P
RESSURE SWIT
C
H DID NO
T OPEN
C
hec
k
f
or
:
-
O
bstr
ucted pressure tube
.
-
P
ressure s
w
itch stuc
k closed.
2
4S
E
C
OND
A
R
Y
V
O
LTA
GE
F
USE IS OPEN
C
hec
k
f
o
r:
-S
h
o
rt
c
ircu
it
in
seco
n
d
a
ry
v
o
lta
ge (
2
4V)
w
ir
in
g
in
clud
in
g ther
most
a
t le
a
ds
.
D
isco
nn
ect ther
most
a
t le
a
ds to
isol
a
te
shor
t c
ircu
it.
3
1
PRESSURE SWIT
C
H DID NO
T
C
LOSE
OR REOPENED – If ope
n
lo
n
ger th
an
5
m
in
ute
s
,
in
ducer shuts off f
o
r
15
m
in
ute
s
bef
o
re retr
y.
If ope
n
s dur
in
g b
lo
w
er o
n
-
del
a
y per
iod, b
lo
w
er
w
ill come o
n
fo
r
th
e
selected b
lo
w
er off-del
a
y.
C
hec
k
f
o
r:
-
P
roper v
e
n
t s
iz
in
g.
-L
o
w
in
ducer v
olt
a
ge (
115
V).
-L
o
w
in
let g
a
s pressure (
if LGPS used).
-I
na
dequ
a
te comb
ust
io
n
ai
r supply
.
-D
isco
nn
ected or obstr
u
cted pressur
e
tub
in
g.
-
D
ef
ect
ive
in
ducer motor
.
-
Def
ect
iv
e
pressure s
w
itch.
-E
x
cess
ive
w
in
d.
-R
e
s
tr
icted v
e
n
t.
33
LI
M
IT
C
IR
C
UIT
F
AU
LT
–
I
n
d
ic
a
tes the
lim
it, dr
a
ft s
a
fegu
a
rd, fl
a
me rollout, or
bl
o
c
ke
d
v
e
n
t shutoff s
w
itch* (
if used)
is
ope
n
. B
lo
w
er w
ill r
u
n
f
o
r 4 m
in
utes or
u
n
ti
l ope
n
sw
itch rem
a
k
es wh
iche
v
er
is
lo
n
ger
. If ope
n
lo
n
ger th
an
3 m
in
utes
,
code ch
an
ges to loc
k
out #
1
3.
If ope
n
less th
an
3 m
in
. st
a
tus code #33
co
n
tin
ues to fl
a
sh u
n
ti
l b
lo
w
er shuts off
.
F
la
me
rollout s
w
itch
an
d BVSS requ
ires
m
an
u
a
l reset.
C
hec
k f
o
r:
-D
ir
ty f
ilter or restr
icted duct system.
-
Loose b
lo
w
er wheel.
-
D
ef
ect
ive
sw
itch or co
nn
ect
io
n
s.
-
D
ef
ect
iv
e
b
lo
w
er motor or c
a
p
a
c
itor
.
-I
na
dequ
a
te comb
ust
io
n
ai
r supply
(fl
a
me rollout s
w
itch ope
n
).
-
Restr
icted v
e
n
t.
-
P
roper v
e
n
t s
iz
in
g.
-E
x
cess
ive
w
in
d.
3
4
IGNITION
PR
O
VING
F
AILURE – If fl
a
me
is
n
ot se
n
sed dur
in
g the tr
ia
l f
o
r
ig
ni
ti
o
n
per
iod, the
co
n
trol w
ill repe
a
t the
ig
ni
ti
o
n
seque
n
ce 3 more t
imes bef
o
re loc
k
out
#
1
4 occurs
. If fl
a
me s
ig
na
l
is lost dur
in
g
the b
lo
w
er o
n
-del
a
y per
iod, b
lo
w
er w
ill
come o
n
f
or the selected b
lo
w
er off-del
a
y.
C
hec
k the f
ollo
w
in
g
items f
irst bef
ore
proceed
in
g to the
n
e
x
t step
.
-G
a
s v
a
lv
e tur
n
ed off
.
-
Man
u
a
l shut-off v
a
lv
e
.
-G
re
e
n/
Ye
llo
w
w
ire
M
UST be co
nn
ected
to fur
na
ce sheet met
a
l.
-
F
la
me se
n
sor must
n
ot be grou
n
ded.
T
o
deter
m
in
e whether the prob
lem
is
in
the g
a
s
va
lv
e
,
ig
ni
ter
, or fl
a
me se
n
sor the
system c
an
be oper
a
ted
in
the compo
n
e
n
t
test mode to chec
k the
ig
ni
ter
.
Fi
rst
remo
ve
the
R ther
most
a
t co
nn
ect
io
n
from
the co
n
trol
an
d
ini
tia
te the compo
n
e
n
t
test seque
n
ce
. Does the
ig
ni
ter gl
ow
or
an
ge
/wh
ite
b
y
the e
n
d
of the
15
seco
n
d
w
a
rm
-up per
iod?
U
n
plug
ig
ni
ter h
a
rn
ess from co
n
trol
an
d
ini
tia
te
an
other compo
n
e
n
t test seque
n
ce
.
C
hec
k
fo
r
115
V betwee
n
p
in
1
an
d NEUTRAL-L
2
o
n
the co
n
trol.
W
a
s
115
V prese
n
t f
o
r the
15
seco
n
d per
iod?
Reco
nn
ect the R ther
most
a
t le
a
d
an
d set
ther
most
a
t to c
a
ll f
or he
a
t.
C
o
nn
ect v
o
ltmeter
a
cross g
a
s v
a
lve
co
nn
ect
io
n
s.
Does g
a
s v
a
lv
e
rece
ive
2
4V?
Does g
a
s v
a
lv
e ope
n
an
d
a
llo
w
g
a
s to flo
w
?
Do the m
ain
bu
rn
ers
ig
ni
te?
Do the m
ain
bu
rn
ers st
a
y o
n
?
Repe
a
t c
a
ll f
o
r he
a
t
an
d chec
k fl
a
me se
n
sor
curre
n
t dur
in
g tr
ia
l f
or
ig
ni
ti
o
n
per
iod.
Is the
D
C
m
icro
a
mps belo
w
0
.5
?
Is curre
n
t
n
e
a
r typ
ic
a
l v
a
lue?
W
ill m
ain
bu
rn
ers
ig
ni
te
an
d st
a
y o
n
?
Fix
ed.
C
le
an
fl
a
me se
n
sor w
ith f
in
e steel wool
an
d
rechec
k curre
n
t.
Nom
ina
l curre
n
t
is 4.
0
to
6
.0
m
icro
a
mps
.
4
5C
ONTR
OL
C
IR
C
UITR
Y LO
C
KO
U
T
A
u
to-reset
a
fter
1
hour loc
k
out due to:
-
F
la
me c
ircu
it f
ai
lure
.
-G
a
s v
a
lv
e rel
a
y stuc
k ope
n
.
-
S
oftw
a
re chec
k error
.
Reset po
wer to cle
a
r lo
c
k
out.
Repl
a
ce
co
n
trol
if code repe
a
ts
.
Repl
a
ce fur
na
ce co
n
trol.
C
hec
k f
or co
n
tin
u
ity
in
the h
a
rn
ess
an
d
ig
ni
te
r.
Repl
a
ce def
e
ct
iv
e compo
n
e
n
t.
C
hec
k co
nn
ect
io
n
s
. If OK, repl
a
ce co
n
trol
.
C
hec
k th
a
t
a
ll g
a
s v
a
lv
es
a
re tur
n
ed o
n
.
Repl
a
ce v
a
lv
e
.
C
hec
k f
o
r:
-I
na
dequ
a
te fl
a
me c
a
rr
y
o
v
er or rough
ig
ni
ti
o
n
.
-L
o
w
in
let g
a
s pressure
.
-
P
roper f
ir
in
g r
a
te
.
-
B
loc
k
ed or
in
correct c
a
rr
y- o
v
er g
a
p.
(.
0
4
5
”
n
om
ina
l)
Allo
w b
lo
w
er to come o
n
an
d repe
a
t test to
chec
k f
or
in
ter
m
itte
n
t oper
a
ti
o
n
.
C
hec
k co
nn
ect
io
n
s
an
d retr
y.
If curre
n
t
is
n
e
a
r typ
ic
a
l v
a
lue (4.
0
-6
.0
n
om
ina
l)
an
d
bu
rn
ers w
ill
n
ot st
a
y o
n
, repl
a
ce co
n
trol.
Repl
a
ce electrode
.
Repl
a
ce fur
na
ce co
n
trol.
* Bloc
k
e
d v
e
n
t shutoff s
w
itch used
in
C
h
im
n
ey
A
d
a
pter K
it
YES
YES
YES
YES
NO
YES
YES
YES
NO
YES
NO
NO
NO
YES
NO
NO
NO
NO
A05032
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
E
2008 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231
Printed in U.S.A.
Edition Date: 10/08
Replaces: II313AAV--- 02
Catalog No. II313AAV---03
313A