beautypg.com

Removing the fan-cage assembly – Lenovo ThinkServer TD200x User Manual

Page 76

background image

Removing the fan-cage assembly

1

Fan cage assembly

2

Fan cage assembly release buttons

To remove the fan-cage assembly, do the following:

1. Read the safety information that begins on page vii and “Handling

static-sensitive devices” on page 39.

2. Turn off the server and peripheral devices, and disconnect the power cords

and all external cables.

3. Turn the server on its side so that it is lying flat, with the side cover facing up.

4. Unlock and remove the left-side cover (see “Removing the left-side cover” on

page 42).

5. Remove the hot-swap power supply or power supplies from the power-supply

cage (see “Removing a hot-swap power supply” on page 63).

6. Rotate the power-supply cage to its open position (see “Opening the

power-supply cage” on page 47).

7. If any full-length PCI adapters are installed, remove them (see “Removing an

adapter” on page 72).

8. Remove the air baffle (see “Removing the air baffle” on page 58).

9. Press the fan cage release latches on each side of the fan cage toward the

sides of the server. The fan cage will lift up slightly when the release latches
are fully open.

10. Grasp the fan-cage assembly and lift it out of the server.

11. If you are instructed to return the fan-cage assembly, follow all packaging

instructions, and use any packaging materials for shipping that are supplied to
you.

60

ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Installation and User Guide