beautypg.com

Server power features, Turning on the server – Lenovo ThinkServer TD200x User Manual

Page 50

background image

The following table describes the problems that are indicated by various
combinations of the power-supply LEDs and the power-on LED on the operator
information panel and suggested actions to correct the detected problems.

Table 5. Power-supply LEDs

Power-supply LEDs

Description

Action

Notes

ac

dc

Error

Off

Off

Off

No ac power to
the server or a
problem with the
ac power source

1. Check the ac power to the server.

2. Make sure that the power cord is

connected to a functioning power
source.

3. Turn the server off and then turn the

server back on.

4. If the problem remains, replace the

power supply.

This is a normal
condition when no
ac power is present.

Off

Off

On

No ac power to
the server or a
problem with the
ac power source
and the power
supply had
detected an
internal problem

1. Replace the power supply.

2. Make sure that the power cord is

connected to a functioning power
source.

This happens only
when a second
power supply is
providing power to
the server.

Off

On

Off

Faulty power
supply

Replace the power supply.

Off

On

On

Faulty power
supply

Replace the power supply.

On

Off

Off

Power supply not
fully seated,
faulty system
board, or faulty
power supply

1. Reseat the power supply.

2. If the system board error LED is off,

replace the power supply.

3. (Trained service technician only) If the

system board error LED is on, replace
the system board.

Typically indicates
that a power supply
is not fully seated.

On

Off or

Flashing

On

Faulty power
supply

Replace the power supply.

On

On

Off

Normal operation

On

On

On

Power supply is
faulty but still
operational

Replace the power supply.

Server power features

When the server is connected to an ac power source but is not turned on, the
operating system does not run, and all core logic except for the integrated
management module (IMM) is shut down; however, the server can respond to
requests from the IMM, such as a remote request to turn on the server. The
power-on LED flashes to indicate that the server is connected to ac power but not
turned on.

Turning on the server

Approximately 3 minutes after the server is connected to ac power, the
power-control button becomes active, and one or more fans might start running to

34

ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Installation and User Guide