Express extender card

1 , if one is installed.

The following illustration shows the LEDs (

1 and 2 ) on the PCI-X extender card,

if one is installed.

The following table describes the LEDs on the system board and extender card and
suggested actions to correct the detected problems.

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Lit EasyLED
diagnostics LED with
the system-error or
information LED also
lit

Description

Action

DIMM 1 to DIMM 16
error LEDs

A DIMM has failed or is incorrectly
installed.

1. Remove the DIMM that is indicated by a lit error

LED.

2. Reseat the DIMM.

3. Replace the following components one at a time,

in the order shown, restarting the server each time:

a. DIMM

b. (Trained service technician only) System board

CPU 1 error LED

Microprocessor 1 has failed, is
missing, or has been incorrectly
installed.
Note: (Trained service technician
only) Make sure that the
microprocessors are installed in the
correct sequence; see the
procedures for removing and
installing a microprocessor in the
Hardware Maintenance Manual.

1. Check the system-event log to determine the

reason for the lit LED.

2. (Trained service technician) Reseat the failing

microprocessor.

3. Replace the following components one at a time,

in the order shown, restarting the server each time:

a. (Trained service technician only) Failing

microprocessor

b. (Trained service technician only) System board