v

Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Lit EasyLED
diagnostics LED with
the system-error or
information LED also
lit

Description

Action

CPU 2 error LED

Microprocessor 2 has failed, is
missing, or has been incorrectly
installed.
Note: (Trained service technician
only) Make sure that the
microprocessors are installed in the
correct sequence; see the
procedures for removing and
installing a microprocessor in the
Hardware Maintenance Manual.

1. Check the system-event log to determine the

reason for the lit LED.

2. Find the failing, missing, or mismatched

microprocessor by checking the LEDs on the
system board.

3. (Trained service technician) Reseat the failing

microprocessor.

4. Replace the following components one at a time,

in the order shown, restarting the server each time:

a. (Trained service technician only) Failing

microprocessor

b. (Trained service technician only) System board

CPU mismatch LED

A mismatched microprocessor has
been installed.
Note: All microprocessors must
have the same speed and cache
size.

1. Run the Setup Utility and view the microprocessor

information to compare the installed
microprocessor specifications.

2. (Trained service technician only) Remove and

replace one of the microprocessors so that they
both match.

VRM failure LED

Microprocessor 2 VRM has failed or
is incorrectly installed.

1. Reseat the VRM

2. Replace the following components one at a time,

in the order shown, restarting the server each time:

a. VRM

b. (Trained service technician only) System board

3. Replace the VRM

System-board error
LED

System-board CPU VRD, power
voltage regulators, or both have
failed.

(Trained service technician only) Replace the system
board.

Battery failure LED

Battery low.

1. Replace the CMOS lithium battery, if necessary.

2. (Trained service technician only) Replace the

system board.