beautypg.com

Software problems, Universal serial bus (usb) port problems, Solving power problems – Lenovo ThinkServer TD200x User Manual

Page 154

background image

Software problems

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Symptom

Action

You suspect a software
problem.

1. To determine whether the problem is caused by the software, make sure that:

v

The server has the minimum memory that is needed to use the software. For
memory requirements, see the information that comes with the software. If
you have just installed an adapter or memory, the server might have a
memory-address conflict.

v

The software is designed to operate on the server.

v

Other software works on the server.

v

The software works on another server.

2. If you receive any error messages while you use the software, see the

information that comes with the software for a description of the messages and
suggested solutions to the problem.

3. Contact the software vendor.

Universal Serial Bus (USB) port problems

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Symptom

Action

A USB device does not work.

1. Run USB diagnostics (see “Running the diagnostic programs” on page 174).

2. Make sure that:

v

The correct USB device driver is installed.

v

The operating system supports USB devices.

v

A standard PS/2 keyboard or mouse is not connected to the server. If it is, a
USB keyboard or mouse will not work during POST.

3. Make sure that the USB configuration optional devices are set correctly in the

Setup Utility (see “Setup Utility menu choices” on page 104 for more
information).

4. If you are using a USB hub, disconnect the USB device from the hub and

connect it directly to the server.

Solving power problems

Power problems can be difficult to solve. For example, a short circuit can exist
anywhere on any of the power distribution buses. Usually, a short circuit will cause
the power subsystem to shut down because of an overcurrent condition. To
diagnose a power problem, use the following general procedure:

1. Turn off the server and disconnect all ac power cords.

138

ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Installation and User Guide