Function fittings and flow controls – Norgren Flow Controls User Manual
Page 32

FIT-3-32
Littleton, CO USA
Phone 303-794-2611
www.norgren.com
Function Fittings and Flow Controls
● Allow two independent signal sources to be
connected to a common pilot line
● Can be used to perform an ‘OR’ logic function
● Selects the highest of two applied pressures
● Can be combined to operate from three or more
sources
● Valves can be ganged together
T65 Series 1/8" and 1/4"
NPT and ISO G Shuttle Valves
Technical Data
Fluid:
Compressed air, filtered, lubricated and non-lubricated, inert gases
Operation:
Shuttle valve
Mounting:
Through holes in valve body
Port Size:
Female Thread
NPT
ISO G
1⁄8 NPT T65A1800
G1⁄8 T65C1800
1⁄4 NPT T65A2800
G1⁄4 T65C2800
Operating Pressure:
10 to 145 psi (0.7 - 10 bar)
Operating Temperature:
0° to 175°F (-20°* to +80°C)
*Consult our Technical Service for use below 35°F (2˚C)
Materials
Body: Zinc
Ball: Nitrile
Seat: Brass
Ordering Information
To order, quote model number from table on page.
FIT-3-19, e.g. T65A1800 for the 1/8" NPT.
1
11
2
2
1