Val- 30, Valve manifolds vs26 series, Valves – Norgren VS26 Series Valve Manifolds User Manual
Page 5

Valves
www.norgren.com/usa
VAL-
30
Valve Manifolds VS26 Series
Plug-in Mini ISO Valves
2x2/2, 2x3/2, 5/2 and 5/3 valves, ISO 15407-2, Size 26 mm
Model
Function
Actuation
Pilot
Pilot pressure
Operating
Manual
Voltage
supply
psi (bar)
pressure psi (bar)
override
VS26G611DF313A
APB
Sol/Sol
Internal
-
29 to 145 (2 to 10)
Push only
24V DC 1.2W
VS26G611DF318A
APB
Sol/Sol
Internal
-
29 to 145 (2 to 10)
Push only
115V AC 1.5VA
VS26G611DF213A
APB
Sol/Sol
Internal
-
29 to 145 (2 to 10)
Push & turn
24V DC 1.2W
VS26G611DF218A
APB
Sol/Sol
Internal
-
29 to 145 (2 to 10)
Push & turn
115V AC 1.5VA
VS26G611DF513A
APB
Sol/Sol
Internal
-
29 to 145 (2 to 10)
Extended, push only
24V DC 1.2W
VS26G611DF518A
APB
Sol/Sol
Internal
-
29 to 145 (2 to 10)
Extended, push only
115V AC 1.5VA
VS26G622DF313A
APB
Sol/Sol
External
29 to 145 (2 to 10)
26" Hg to 232 (-0.9 to 16)
Push only
24V DC 1.2W
VS26G622DF318A
APB
Sol/Sol
External
29 to 145 (2 to 10)
26" Hg to 232 (-0.9 to 16)
Push only
115V AC 1.5VA
VS26G622DF213A
APB
Sol/Sol
External
29 to 145 (2 to 10)
26" Hg to 232 (-0.9 to 16)
Push & turn
24V DC 1.2W
VS26G622DF218A
APB
Sol/Sol
External
29 to 145 (2 to 10)
26" Hg to 232 (-0.9 to 16)
Push & turn
115V AC 1.5VA
VS26G622DF513A
APB
Sol/Sol
External
29 to 145 (2 to 10)
26" Hg to 232 (-0.9 to 16)
Extended, push only
24V DC 1.2W
VS26G622DF518A
APB
Sol/Sol
External
29 to 145 (2 to 10)
26" Hg to 232 (-0.9 to 16)
Extended, push only
115V AC 1.5VA
VS26G711DF313A
COE
Sol/Sol
Internal
-
29 to 145 (2 to 10)
Push only
24V DC 1.2W
VS26G711DF318A
COE
Sol/Sol
Internal
-
29 to 145 (2 to 10)
Push only
115V AC 1.5VA
VS26G711DF213A
COE
Sol/Sol
Internal
-
29 to 145 (2 to 10)
Push & turn
24V DC 1.2W
VS26G711DF218A
COE
Sol/Sol
Internal
-
29 to 145 (2 to 10)
Push & turn
115V AC 1.5VA
VS26G711DF513A
COE
Sol/Sol
Internal
-
29 to 145 (2 to 10)
Extended, push only
24V DC 1.2W
VS26G711DF518A
COE
Sol/Sol
Internal
-
29 to 145 (2 to 10)
Extended, push only
115V AC 1.5VA
VS26G722DF313A
COE
Sol/Sol
External
29 to 145 (2 to 10)
26" Hg to 232 (-0.9 to 16)
Push only
24V DC 1.2W
VS26G722DF318A
COE
Sol/Sol
External
29 to 145 (2 to 10)
26" Hg to 232 (-0.9 to 16)
Push only
115V AC 1.5VA
VS26G722DF213A
COE
Sol/Sol
External
29 to 145 (2 to 10)
26" Hg to 232 (-0.9 to 16)
Push & turn
24V DC 1.2W
VS26G722DF218A
COE
Sol/Sol
External
29 to 145 (2 to 10)
26" Hg to 232 (-0.9 to 16)
Push & turn
115V AC 1.5VA
VS26G722DF513A
COE
Sol/Sol
External
29 to 145 (2 to 10)
26" Hg to 232 (-0.9 to 16)
Extended, push only
24V DC 1.2W
VS26G722DF518A
COE
Sol/Sol
External
29 to 145 (2 to 10)
26" Hg to 232 (-0.9 to 16)
Extended, push only
115V AC 1.5VA
5/3 Double solenoid actuated Glandless valves flow = 1.02 sscfm (1000 l/min)
Model
Function
Actuation
Pilot
Pilot pressure
Operating
Manual
Voltage
supply
psi (bar)
pressure psi (bar)
override
VS26S611DF313A
APB
Sol/Sol
Internal
-
36 to 145 (2.5 to 10)
Push only
24V DC 1.2W
VS26S611DF318A
APB
Sol/Sol
Internal
-
36 to 145 (2.5 to 10)
Push only
115V AC 1.5VA
VS26S611DF213A
APB
Sol/Sol
Internal
-
36 to 145 (2.5 to 10)
Push & turn
24V DC 1.2W
VS26S611DF218A
APB
Sol/Sol
Internal
-
36 to 145 (2.5 to 10)
Push & turn
115V AC 1.5VA
VS26S611DF513A
APB
Sol/Sol
Internal
-
36 to 145 (2.5 to 10)
Extended, push only
24V DC 1.2W
VS26S611DF518A
APB
Sol/Sol
Internal
-
36 to 145 (2.5 to 10)
Extended, push only
115V AC 1.5VA
VS26S622DF313A
APB
Sol/Sol
External
36 to 145 (2.5 to 10)
26" Hg to 145 (-0.9 to 10)
Push only
24V DC 1.2W
VS26S622DF318A
APB
Sol/Sol
External
36 to 145 (2.5 to 10)
26" Hg to 145 (-0.9 to 10)
Push only
115V AC 1.5VA
VS26S622DF213A
APB
Sol/Sol
External
36 to 145 (2.5 to 10)
26" Hg to 145 (-0.9 to 10)
Push & turn
24V DC 1.2W
VS26S622DF218A
APB
Sol/Sol
External
36 to 145 (2.5 to 10)
26" Hg to 145 (-0.9 to 10)
Push & turn
115V AC 1.5VA
VS26S622DF513A
APB
Sol/Sol
External
36 to 145 (2.5 to 10)
26" Hg to 145 (-0.9 to 10)
Extended, push only
24V DC 1.2W
VS26S622DF518A
APB
Sol/Sol
External
36 to 145 (2.5 to 10)
26" Hg to 145 (-0.9 to 10)
Extended, push only
115V AC 1.5VA
VS26S711DF313A
COE
Sol/Sol
Internal
-
36 to 145 (2.5 to 10)
Push only
24V DC 1.2W
VS26S711DF318A
COE
Sol/Sol
Internal
-
36 to 145 (2.5 to 10)
Push only
115V AC 1.5VA
VS26S711DF213A
COE
Sol/Sol
Internal
-
36 to 145 (2.5 to 10)
Push & turn
24V DC 1.2W
VS26S711DF218A
COE
Sol/Sol
Internal
-
36 to 145 (2.5 to 10)
Push & turn
115V AC 1.5VA
VS26S711DF513A
COE
Sol/Sol
Internal
-
36 to 145 (2.5 to 10)
Extended, push only
24V DC 1.2W
VS26S711DF518A
COE
Sol/Sol
Internal
-
36 to 145 (2.5 to 10)
Extended, push only
115V AC 1.5VA
VS26S722DF313A
COE
Sol/Sol
External
36 to 145 (2.5 to 10)
26" Hg to 145 (-0.9 to 10)
Push only
24V DC 1.2W
VS26S722DF318A
COE
Sol/Sol
External
36 to 145 (2.5 to 10)
26" Hg to 145 (-0.9 to 10)
Push only
115V AC 1.5VA
VS26S722DF213A
COE
Sol/Sol
External
36 to 145 (2.5 to 10)
26" Hg to 145 (-0.9 to 10)
Push & turn
24V DC 1.2W
VS26S722DF218A
COE
Sol/Sol
External
36 to 145 (2.5 to 10)
26" Hg to 145 (-0.9 to 10)
Push & turn
115V AC 1.5VA
VS26S722DF513A
COE
Sol/Sol
External
36 to 145 (2.5 to 10)
26" Hg to 145 (-0.9 to 10)
Extended, push only
24V DC 1.2W
VS26S722DF518A
COE
Sol/Sol
External
36 to 145 (2.5 to 10)
26" Hg to 145 (-0.9 to 10)
Extended, push only
115V AC 1.5VA
5/3 Double solenoid actuated Softseal valves flow = 1.37 Cv (1350 L/min)
APB = All ports blocked
COE = Center open to exhaust