beautypg.com

Val- 43, Valve manifolds vs26 series, Fieldbus options: overview – Norgren VS26 Series Valve Manifolds User Manual

Page 18: Bus connector: d-sub 9-pin, Power connector: m12 4-pin, Bus connector: m12 5-pin (b-coded), Power connector: 7/8 5-pin

background image

VAL-

43

Valve Manifolds VS26 Series

Profibus DP

1 x D-Sub 9-pin

M12 4-pin

04/05/06/07/08/09/10/11/12/13/14/15/16

32

2 x M12 5-pin

M12 4-pin

04/05/06/07/08/09/10/11/12/13/14/15/16

32

2 x M12 5-pin

7/8 5-pin

04/05/06/07/08/09/10/11/12/13/14/15/16

32

Interbus-S

2 x D-Sub 9-pin

M12 4-pin

04/05/06/07/08/09/10/11/12/13/14/15/16

32

AS-Interface - Single slave

1 x M12 4-pin

M12 4-pin

02/03/04

4

AS-Interface - Double slave

1 x M12 4-pin

M12 4-pin

04/05/06/07/08

8

DeviceNet

1 x M12 5-pin

M12 4-pin

04/05/06/07/08/09/10/11/12/13/14/15/16

32

CANopen

1 x M12 5-pin

M12 4-pin

04/05/06/07/08/09/10/11/12/13/14/15/16

32

AB RIO

2 x M12 5-pin

M12 4-pin

04/05/06/07/08/09/10/11/12/13/14/15/16

32

For parts and assembly instructions of Fieldbus components, consult our technical service.

2.0

(51)

0.87

(22)

0.63

(16)

0.89

(22.5)

0.85

(21.5)

M 12

Fieldbus protocol: Profibus DP

Connector: 1 x D-Sub 9-pin / M12 4-pin

Connector: 2 x M12 5-pin / M12 4-pin

Bus connector: D-Sub 9-pin

2.32

(59)

0.87

22

1.48

(37.5)

0.63

(16)

0.85

(21.5)

M 12

M 12

M 12

3

2

4

1

Fieldbus options: Overview

1
2
3
4
5
6
7
8
9

Shield
N/C
B-line (red) RxD / TxD-P
N/C
DGND (OVI) isolated
VP (5VI) isolated
N/C
A-line (green) RxD / TxD-N
N/C

1

300 mA

2

1)

3

2)

4

-

Power connector: M12 4-pin

Bus connector: M12 5-pin (B-coded)

1

300 mA

2

1)

3

2)

4

-

24 VB logic circuit supply

+/-25%

24 VA valves

+/-10%

0 volts

Earth

Power connector: M12 4-pin

2.36

(60)

0.75

(19)

0.73

(18.5)

1.63

(41.5)

0.73

(18.5)

1.16

(29.5)

0.85

(21.5)

M 12

M 12

3

2

4

1

Bus connector: M12 5-pin (B-coded)

1
2
3
4
5

Pin no.

Function

Tolerance

Max.
current

1

-

-

-

2

0 volts

-

2)

3

Earth

-

-

4

24 VA valves

+/-10%

1)

5

24 VB logic circuit supply

+/-25%

300 mA

Power connector: 7/8 5-pin

4

1

5

3

2

3

2

5

4

1

4

1

5

3

2

3

2

5

4

1

1

2

3

4

1

2

3

4

3

4

2

5

1

2

3

4

6

7

8

9

1

5

Male

Male

Female

Communication in

Male

Male

Communication out

Female

Communication

in/out

Male

Female

Communication in Communication out

Supply voltage connector
(Fieldbus and valves)

Max. no.
coils

No. of stations

Fieldbus
interface/connector

Fieldbus protocol

Connector: 2 x M12 5-pin / 7/8 5-pin

Pin no.

Function

Pin no.

Function

Pin no.

Function

Tolerance

Max.
current

Pin no.

Pin no.

Function

Function

Tolerance

Max.
current

1
2
3
4
5

5VI opto isolated
A-line (green)
OVI isolated
B-line (red)
Shield
Shield

Threaded joint

Threaded joint

5VI isolated
A-line (green)
OVI isolated
B-line (red)
Shield
Shield

1) I

max = 10 mA + n*60 mA

n = number of energized solenoids

2) I

max = IVA + IVB

24 VB logic circuit supply +/-25%
24 VA valves

+/-10%

0 volts

Earth