Model

Function

Actuation

Pilot

Pilot pressure

Operating

Manual

Voltage

supply

psi (bar)

pressure psi (bar)

override

VS26S511DF313A

5/2

Sol/Sol

Internal

-

29 to 145 (2 to 10)

Push only

24V DC 1.2W

VS26S511DF318A

5/2

Sol/Sol

Internal

-

29 to 145 (2 to 10)

Push only

115V AC 1.5VA

VS26S511DF213A

5/2

Sol/Sol

Internal

-

29 to 145 (2 to 10)

Push & turn

24V DC 1.2W

VS26S511DF218A

5/2

Sol/Sol

Internal

-

29 to 145 (2 to 10)

Push & turn

115V AC 1.5VA

VS26S511DF513A

5/2

Sol/Sol

Internal

-

29 to 145 (2 to 10)

Extended, push only

24V DC 1.2W

VS26S511DF518A

5/2

Sol/Sol

Internal

-

29 to 145 (2 to 10)

Extended, push only

115V AC 1.5VA

VS26S522DF313A

5/2

Sol/Sol

External

29 to 145 (2 to 10)

26" Hg to 145 (-0.9 to 10)

Push only

24V DC 1.2W

VS26S522DF318A

5/2

Sol/Sol

External

29 to 145 (2 to 10)

26" Hg to 145 (-0.9 to 10)

Push only

115V AC 1.5VA

VS26S522DF213A

5/2

Sol/Sol

External

29 to 145 (2 to 10)

26" Hg to 145 (-0.9 to 10)

Push & turn

24V DC 1.2W

VS26S522DF218A

5/2

Sol/Sol

External

29 to 145 (2 to 10)

26" Hg to 145 (-0.9 to 10)

Push & turn

115V AC 1.5VA

VS26S522DF513A

5/2

Sol/Sol

External

29 to 145 (2 to 10)

26" Hg to 145 (-0.9 to 10)

Extended, push only

24V DC 1.2W

VS26S522DF518A

5/2

Sol/Sol

External

29 to 145 (2 to 10)

26" Hg to 145 (-0.9 to 10)

Extended, push only

115V AC 1.5VA

VS26S517DF313A

5/2

Sol/Spring

Internal

-

29 to 145 (2 to 10)

Push only

24V DC 1.2W

VS26S517DF318A

5/2

Sol/Spring

Internal

-

29 to 145 (2 to 10)

Push only

115V AC 1.5VA

VS26S517DF213A

5/2

Sol/Spring

Internal

-

29 to 145 (2 to 10)

Push & turn

24V DC 1.2W

VS26S517DF218A

5/2

Sol/Spring

Internal

-

29 to 145 (2 to 10)

Push & turn

115V AC 1.5VA

VS26S517DF513A

5/2

Sol/Spring

Internal

-

29 to 145 (2 to 10)

Extended, push only

24V DC 1.2W

VS26S517DF518A

5/2

Sol/Spring

Internal

-

29 to 145 (2 to 10)

Extended, push only

115V AC 1.5VA

VS26S527DF313A

5/2

Sol/Spring

External

29 to 145 (2 to 10)

26" Hg to 145 (-0.9 to 10)

Push only

24V DC 1.2W

VS26S527DF318A

5/2

Sol/Spring

External

29 to 145 (2 to 10)

26" Hg to 145 (-0.9 to 10)

Push only

115V AC 1.5VA

VS26S527DF213A

5/2

Sol/Spring

External

29 to 145 (2 to 10)

26" Hg to 145 (-0.9 to 10)

Push & turn

24V DC 1.2W

VS26S527DF218A

5/2

Sol/Spring

External

29 to 145 (2 to 10)

26" Hg to 145 (-0.9 to 10)

Push & turn

115V AC 1.5VA

VS26S527DF513A

5/2

Sol/Spring

External

29 to 145 (2 to 10)

26" Hg to 145 (-0.9 to 10)

Extended, push only

24V DC 1.2W

VS26S527DF518A

5/2

Sol/Spring

External

29 to 145 (2 to 10)

26" Hg to 145 (-0.9 to 10)

Extended, push only

115V AC 1.5VA

5/2 Single and double solenoid actuated Softseal valves flow = 1.37 Cv (1350 L/min)

Model

Function Actuation

Pilot

Pilot pressure

Operating

Manual

Voltage

supply

psi (bar)

pressure psi (bar)

override

VS26G511DF313A

5/2

Sol/Sol

Internal

-

29 to 145 (2 to 10)

Push only

24V DC 1.2W

VS26G511DF318A

5/2

Sol/Sol

Internal

-

29 to 145 (2 to 10)

Push only

115V AC 1.5VA

VS26G511DF213A

5/2

Sol/Sol

Internal

-

29 to 145 (2 to 10)

Push & turn

24V DC 1.2W

VS26G511DF218A

5/2

Sol/Sol

Internal

-

29 to 145 (2 to 10)

Push & turn

115V AC 1.5VA

VS26G511DF513A

5/2

Sol/Sol

Internal

-

29 to 145 (2 to 10)

Extended, push only

24V DC 1.2W

VS26G511DF518A

5/2

Sol/Sol

Internal

-

29 to 145 (2 to 10)

Extended, push only

115V AC 1.5VA

VS26G522DF313A

5/2

Sol/Sol

External

29 to 145 (2 to 10)

26" Hg to 232 (-0.9 to 16)

Push only

24V DC 1.2W

VS26G522DF318A

5/2

Sol/Sol

External

29 to 145 (2 to 10)

26" Hg to 232 (-0.9 to 16)

Push only

115V AC 1.5VA

VS26G522DF213A

5/2

Sol/Sol

External

29 to 145 (2 to 10)

26" Hg to 232 (-0.9 to 16)

Push & turn

24V DC 1.2W

VS26G522DF218A

5/2

Sol/Sol

External

29 to 145 (2 to 10)

26" Hg to 232 (-0.9 to 16)

Push & turn

115V AC 1.5VA

VS26G522DF513A

5/2

Sol/Sol

External

29 to 145 (2 to 10)

26" Hg to 232 (-0.9 to 16)

Extended, push only

24V DC 1.2W

VS26G522DF518A

5/2

Sol/Sol

External

29 to 145 (2 to 10)

26" Hg to 232 (-0.9 to 16)

Extended, push only

115V AC 1.5VA

VS26G517DF313A

5/2

Sol/Spring

Internal

-

23 to 145 (1.6 to 10)

Push only

24V DC 1.2W

VS26G517DF318A

5/2

Sol/Spring

Internal

-

23 to 145 (1.6 to 10)

Push only

115V AC 1.5VA

VS26G517DF213A

5/2

Sol/Spring

Internal

-

23 to 145 (1.6 to 10)

Push & turn

24V DC 1.2W

VS26G517DF218A

5/2

Sol/Spring

Internal

-

23 to 145 (1.6 to 10)

Push & turn

115V AC 1.5VA

VS26G517DF513A

5/2

Sol/Spring

Internal

-

23 to 145 (1.6 to 10)

Extended, push only

24V DC 1.2W

VS26G517DF518A

5/2

Sol/Spring

Internal

-

23 to 145 (1.6 to 10)

Extended, push only

115V AC 1.5VA

VS26G527DF313A

5/2

Sol/Spring

External

23 to 145 (1.6 to 10)

26" Hg to 232 (-0.9 to 16)

Push only

24V DC 1.2W

VS26G527DF318A

5/2

Sol/Spring

External

23 to 145 (1.6 to 10)

26" Hg to 232 (-0.9 to 16)

Push only

115V AC 1.5VA

VS26G527DF213A

5/2

Sol/Spring

External

23 to 145 (1.6 to 10)

26" Hg to 232 (-0.9 to 16)

Push & turn

24V DC 1.2W

VS26G527DF218A

5/2

Sol/Spring

External

23 to 145 (1.6 to 10)

26" Hg to 232 (-0.9 to 16)

Push & turn

115V AC 1.5VA

VS26G527DF513A

5/2

Sol/Spring

External

23 to 145 (1.6 to 10)

26" Hg to 232 (-0.9 to 16)

Extended, push only

24V DC 1.2W

VS26G527DF518A

5/2

Sol/Spring

External

23 to 145 (1.6 to 10)

26" Hg to 232 (-0.9 to 16)

Extended, push only

115V AC 1.5VA

5/2 Single and double solenoid actuated Glandless valves flow = 1.02 Cv (1000 l/min)

Valve Manifolds VS26 Series

Plug-in Mini ISO Valves

2x2/2, 2x3/2, 5/2 and 5/3 valves, ISO 15407-2,

Size 26 mm