Characteristics and specifications, Recommended operating conditions, Power measurement characteristics – Cirrus Logic CS5484 User Manual
Page 9: Typical load performance, Figure 4. active energy load performance, Cs5484

CS5484
DS981F3
9
3. CHARACTERISTICS AND SPECIFICATIONS
RECOMMENDED OPERATING CONDITIONS
POWER MEASUREMENT CHARACTERISTICS
Notes: 1.
Specifications
guaranteed
by design and characterization.
2.
Active energy is tested with power factor (PF) = 1.0. Reactive energy is tested with Sin(
) = 1.0. Energy error measured at
system level using a single energy pulse. Where: 1) One energy pulse = 0.5Wh or 0.5Varh; 2) VDDA = +3.3V, T
A
= 25°C, MCLK
= 4.096MHz; 3) System is calibrated.
3.
Calculated using register values; N
≥
4000.
4.
I
RMS
error calculated using register values. 1) VDDA = +3.3V; T
A
= 25°C; MCLK = 4.096MHz; 2) AC offset calibration applied.
TYPICAL LOAD PERFORMANCE
• Energy error measured at system level using single energy pulse; where one energy pulse = 0.5Wh or 0.5Varh
• I
RMS
error calculated using register values
• VDDA = +3.3V; T
A
= 25°C; MCLK = 4.096MHz
Parameter
Symbol Min Typ
Max
Unit
Positive Analog Power Supply
VDDA
3.0
3.3
3.6
V
Specified Temperature Range
T
A
-40
-
+85
°C
Parameter
Symbol Min Typ
Max
Unit
Active Energy
All Gain Ranges
Current Channel Input Signal Dynamic Range 4000:1
P
Avg
-
±0.1
-
%
Reactive Energy
All Gain Ranges
Current Channel Input Signal Dynamic Range 4000:1
Q
Avg
-
±0.1
-
%
Apparent Power
All Gain Ranges
Current Channel Input Signal Dynamic Range 1000:1
S
-
±0.1
-
%
Current RMS
All Gain Ranges
Current Channel Input Signal Dynamic Range 1000:1
I
RMS
-
±0.1
-
%
Voltage RMS
Voltage Channel Input Signal Dynamic Range 20:1
V
RMS
-
±0.1
-
%
Power Factor
All Gain Ranges
Current Channel Input Signal Dynamic Range 1000:1
PF
-
±0.1
-
%
-1
-0.5
0
0.5
1
0
500
1000
1500
2000
2500
3000
3500
4000
4500
Perce
nt Erro
r (%)
Current Dynamic Range (x : 1
)
Lagging PF = 0.5
Leading PF = 0.5
PF = 1
Figure 4. Active Energy Load Performance