Section 4 Troubleshooting

40

Code Sync Status

The Code Sync Status will indicate NO on the TRACER System Status page when the link is down or
not operational. The Code Sync Status will indicate NO when data synchronization has not been
achieved between each end of the RF link.

Recommended Action

Possible Cause

(see list below)

The RF link is down .................................................................................. 1-10

The RX power is below the specified receiver sensitivity .................... 1-4,7-10

The far-end transmitter is off, or is transmitting low power .............. 1-4,7-10

The RF path is not aligned ...................................................................... 1,3,10

Water is in the antenna feedhorn or connectors .......................................... 1,4

Both units are set to the same frequency ................................................... 5,10

Both units are not set to the same P/N code ................................................... 6

The connection between the BBP and the RFC is faulty ....................... 1,7-10

The connection between the RFC and the antenna is faulty .................. 1,7-10

The BBP or RFC is faulty ............................................................................. 10

Recommended Actions:

1.

Check the RX power using the VT100 user interface or RSSI voltage.

2.

Check the far-end transmitter for operation and proper transmit power.

3.

Check the RF path using a spectrum analyzer or RSSI voltages for proper alignment. Have

path professionally re-aligned and check system path engineering.

4.

Check the antenna feedhorn and all outdoor connections for water.

5.

Change the frequency of one radio through the VT100 user interface or front panel button.

6.

Set both units to the same P/N code.

7.

Check all connections between the BBP, the RFC, and the antenna.

8.

Check the IF and RF cables for shorts.

9.

Check connections inside the mastmount or rackmount RFC.

10. Replace the RFC.

I M P O R T A N T

If problems persist after you have followed the Recommended Actions, contact ADTRAN
Technical Support at (011) 256-963-8716.